6.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Settings, press the ENTER button to
confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the
present address will blink on the display, use the UP/DOWN button to adjust the address from 001
to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the
unit idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
14 channels
1
15
29
43
12 channels
1
13
25
37
6.3 DMX512 Configuration
Please control the fixture by referring to the configurations below
Attentions:
1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
2. For the channel Function, keep the value for about 3 seconds, then the corresponding function
will take into effect.