7. Error Information
1. CPU-B/C Error
Check whether the 485 (DATA) leads on the PCB board are installed in place or disconnected.
Check whether the 485 (DATA) lead is disconnected.
Check whether the relevant signal circuit 485 (DATA) on the PCB board is damaged.
2. Pan Reset Error
Check if the position of the pan mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the pan operating range.
Check if the pan Hall elements is damaged.
Check if the pan Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the pan motor is damaged.
Check if there is any damage to the circuit of the pan motor drive board.
3. Pan Encode Error
Check if the pan encoder is damaged.
Check if the pan encoder is in poor contact with the lead of the PCB board or disconnected.
4. Tilt Reset Error
Check if the position of the tilt mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the tilt operating range.
Check if the tilt Hall elements is damaged.
Check if the tilt Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the tilt motor is damaged.
Check if there is any damage to the circuit of the tilt motor drive board.
5. Tilt Encode Error
Check if the tilt encoder is damaged.
Check if the tilt encoder is in poor contact with the lead of the PCB board or disconnected.
25A