background image

 
 

 

    11.   SLAVE   

    On   

    Slave   Mode   

    12.   SOUND   

    Flashing   

    Sound   activation   

   

13.   SPEED:   

Manually   adjusts   strobe   speed.   (Left   to   right,   the   speed   is   from   slow   to   fast)       

Note:   

To   activate   the   manual   

DIMMER

   and

   SPEED

   controls,   scroll   through   the   MENU   and   

ENTER   

    mode   then   select   

 

(Manual),   the   manual   controls   will   function   

only   in   this   mode.

   

14.   DIMMER:   

Manually   adjusts   dimmer.   (Left   to   right,   the   brightness   is   from   min   to   max)

   

15.   MICROPHONE:   

Receives   music   signal   for   sound   active   mode.

   

16.   ONLY   FOR   REMOTE   CONTROL:   

Connects   to   the   optional   CA-­‐8   to   control   the   unit   in   Stand-­‐by,   

Function   and   Mode   

17.   DMX   INPUT:

   DMX   512   link,   use   a   3-­‐pin   XLR   cable   to   link   the   unit   and   DMX   controller,   

18.   DMX   OUTPUT:   

DMX   512   link,   use   a   3-­‐pin   XLR   cable   to   link   to   the   next   unit.   

3.2   Main   Functions       

To    select    any    of    the    given    functions,    press    the   

MENU

    button    up    to    the    required    selection    as   

shown   on   the   display.   Select   the   function   by   pressing   the   

ENTER

   button   and   the   display   will   blink.   

Use    the   

DOWN

/

UP

    buttons    to    change    the    mode.    Once    the    required    mode    has    been    selected,   

press   the   

ENTER

   button   to   confirm.   To   go   back   to   the   main   functions   without   any   changes   press   

the

    MENU

    button    again.    Press    and    hold    the   

MENU

    button    for    about    one    second    or    wait    for    7   

seconds   to   exit   the   current   mode.   

   

The   main   functions   are   shown   overleaf:   

 

 

 

 

 

 

 

 

Summary of Contents for LED STROBE 50

Page 1: ...LED ST50 User Manual Please read the instruction carefully before use ...

Page 2: ... The Unit 4 3 1 Control panel 4 3 2 Main Functions 5 4 How To Control The Unit 9 4 1 Master Slave Built In Pre programmed Function 10 4 2 Easy Controller CA 8 10 4 3 DMX Controller 11 5 DMX 512 Configuration 11 6 DMX 512 Connection 14 7 Troubleshooting 14 8 Fixture Cleaning 15 ...

Page 3: ...materials close to the unit while operating as it is fire hazard Use safety cables when installing this unit DO NOT handle the unit by taking its head only but always carry by its base Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by ...

Page 4: ...ble that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed in a place where it is out of the reach of people and no one can pass by or under it 2 Technical Specifications 5 DMX Channel Modes 1 2 10 12 3 Operation modes DMX Master Slave mode Sound Activation Variable strobe speed and intensity Built in programs ...

Page 5: ...supply 3 POWER OUT Connect to supply power to the next fixture 4 DISPLAY To show the various menus and the selected functions BUTTON 5 MENU To select the programming functions 6 DOWN To go backward in the selected functions 7 UP To go forward in the selected functions 8 ENTER To confirm the selected functions LED 9 DMX On DMX input present 10 MASTER On Master Mode ...

Page 6: ... Stand by Function and Mode 17 DMX INPUT DMX 512 link use a 3 pin XLR cable to link the unit and DMX controller 18 DMX OUTPUT DMX 512 link use a 3 pin XLR cable to link to the next unit 3 2 Main Functions To select any of the given functions press the MENU button up to the required selection as shown on the display Select the function by pressing the ENTER button and the display will blink Use the...

Page 7: ...6 ...

Page 8: ...s and hold the MENU button for about one second or wait for one minute to exit the menu mode SLAVE MODE To select press the ENTER button to show the SLAVE MODE on the display Use the DOWN UP buttons to select the SLAVE 1 SLAVE 2 modes Once the mode has been selected press the ENTER button to setup To go back to the functions without any changes press the MENU button again Press and hold the MENU b...

Page 9: ...without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode BLACKOUT MODE To select press the ENTER button to show BLACKOUT MODE on the display Use the DOWN UP buttons to select the blackout or normal mode Once the mode has been selected press the ENTER button to setup To go back to the functions without any chang...

Page 10: ... the functions without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode FIXTURE USE HOURS To select press the ENTER button to show the FIXTURE USE HOURS on the display and the display will show the number of working hours of the unit To go back to the functions without any changes press the MENU button again Pr...

Page 11: ... master mode and select random show or show 1 or or show 12 mode Any other units will have to be set in slave mode and select normal or 2 light show mode 2 light show In slave mode means the unit works normally and means 2 light show In order to create a great light show you can set on the second unit to get contrast movement to each other 4 2 Easy Controller CA 8 The CA 8 remote control is used o...

Page 12: ... will blink Use the DOWN UP buttons to change the DMX 512 address Once the address has been selected press and hold the ENTER button until the display stops blinking or it will store automatically after 7 seconds To go back to the functions without any changes press the MENU button again Please refer to the following diagram to address your DMX 512 channel for the first 4 units 5 DMX 512 Configura...

Page 13: ...12 3 Channels Mode ...

Page 14: ...13 10 Channels Mode 12 Channels Mode ...

Page 15: ...and input connectors are pass through type to maintain the DMX circuit when one of the units power is disconnected 3 Each fixture unit needs to have an address set to receive the data sent by the controller The address number is between 0 512 usually 0 1 are equal to 1 4 The end of the DMX 512 system should be terminated to reduce signal errors 7 Troubleshooting Following are a few common problems...

Page 16: ...ng Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the unit Set the correct address D No response to the sound 1 Make sure the unit is set into the correct mode 2 Check the microphone by tapping it 3 Make sure the fixture is not set into Blackout mode 8 Fixture Cleaning The cleaning must be carried out periodically to optimize light output Cleaning frequency d...

Page 17: ...16 ...

Page 18: ...th the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 19: ...18 Innovation Quality Performance ...