background image

Summary of Contents for STAGE PAR 400 ZOOM IP

Page 1: ......

Page 2: ...cal Specifications 4 3 How To Set The Fixture 5 3 1 Control Panel 5 3 2 Main Functions 6 4 How To Control The Unit 13 4 1 DMX512 Controller 14 4 2 DMX512 Configuration 14 4 3 DMX512 Connection 18 5 Tr...

Page 3: ...ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power su...

Page 4: ...tion Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the original packing materials be...

Page 5: ...channels Control Mode DMX512 RDM Firmware Upgrade via DMX link Construction Display OLED display Data In Out 5 pin IP XLR Power In Out Waterproof Power Connector in out Protection Rating IP66 Feature...

Page 6: ...Dimensions Weight 295x316x318mm 8 5kgs 11 6 x12 4 x12 5 in 18 7lbs Photometrics Diagram 3 How To Set The Fixture 3 1 Control Panel 5G...

Page 7: ...pply power 6 POWER OUT Connects to the next fixture 3 2 Main Functions Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is shown on the mo...

Page 8: ...7G...

Page 9: ...To select DMX State press the ENTER button to confirm use the UP DOWN button to select Last State Blackout or Show Fixture Setting To select Fixture Setting press the ENTER button to confirm use the U...

Page 10: ...l is coarser at low levels and finger at high levels S Curve Light intensity control is finger at low levels and high levels and coarser at medium levels Dimmer Speed To select Dimmer Speed press the...

Page 11: ...me To select Fade Time press the ENTER button to confirm Use the UP DOWN button to adjust the value from 0 to 255 Press the MENU button back to the last menu or let the unit idle 30 seconds to exit me...

Page 12: ...on back to the last menu or let the unit idle 30 seconds to exit menu mode Temperature Unit Select Temperature Unit press the ENTER button to confirm present mode will blink on the display use the UP...

Page 13: ...to exit Firmware Version Select Firmware Version press the ENTER button to confirm firmware version will show on the display press the MENU button back to exit RDM UID Select RDM UID press the ENTER...

Page 14: ...menu and the program version number of the fixture will be displayed Select the DMX START ADDRESS menu to change the DMX 512 address 001 512 Select the DEVICE MODEL DESCRIPTION menu to display the mo...

Page 15: ...k to the last menu or let the unit idle 30 seconds to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Addre...

Page 16: ...043 070 071 078 079 106 107 114 115 142 143 150 151 178 179 186 187 214 215 222 223 250 251 255 STROBE Open Strobe from fast to slow Pulse from fast to slow Random Strobe Burst from fast to slow Rand...

Page 17: ...fast to slow Random burst Burst pulse from fast to slow Random burst pulse Slow open Fast close Random slow open fast close Fast open Slow close Random fast open slow close Slow open slow close Open...

Page 18: ...ll CT Blue LEE 202 Half CT Blue LEE 117 Steel Blue LEE 353 Lighter Blue LEE 118 Light Blue LEE 116 Medium Blue Green LEE 124 Dark Green LEE 139 Primary Green LEE 089 Moss Green LEE 122 Fem Green LEE 7...

Page 19: ...damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when on...

Page 20: ...her DMX controller 5 Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working...

Page 21: ...20G...

Page 22: ...21G...

Page 23: ...ars CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 2014 30 EU EN 55032 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55103 2 2009 Harmonized Standard EN 6059...

Page 24: ...Innovation Quality Performance...

Reviews: