1.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the
DMX-output of the last unit.
2.
Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to
the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a
very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors
can easily distort the signal and shut down the system.
3.
The DMX output and input connectors are pass-through to maintain the DMX circuit, when
one of the units’ power is disconnected.
4.
Each lighting unit needs to have a DMX address to receive the data by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1).
5.
The end of the DMX 512 system should be terminated to reduce signal errors.
6.
3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.
7.2 Channel Mode Setting
Enter menu mode, select
DMX Functions
, press the
ENTER
button to confirm, use the
UP/DOWN
button to select
Mode
, press the
ENTER
button to confirm, present channel mode will blink on the
display, use the
UP/DOWN
button to select
16 Channel
、
15 Channel
、
19 Channel
or
20 Channel
Mode, and press the
ENTER
button to store. Press the
MENU
button back to the last menu or let
the unit idle one minute to exit menu mode.
A
18A