240-247
248-255
Strobe Random
Open
21
000 - 255
DIMMER
:
0%
100%
8. Troubleshooting
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1.
Check the connect power and main fuse.
2.
Measure the mains voltage on the main connector.
3.
Check the power on LED to see if it can be light up or not.
B. Not responding to DMX controller
1.
DMX LED should be on. If not, check DMX connectors, cables to see if they are linked
properly.
2.
If the DMX LED is on and no response to the channel, check the address settings and DMX
polarity.
3.
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the
unit or the previous one.
4.
Try to use another DMX controller.
5.
Check to see if the DMX cables run near or run alongside high voltage cables that may cause
damage or interference to DMX interface circuit.
C. One of the channels is not working well
1.
The stepper motor might be damaged or the cable connected to the PCB is broken.
2.
The motor’s drive IC on the PCB might be out of condition.
D. The lamp is cutting out intermittently
1.
The lamp is not working well. Check the mains voltage either too high or too low.
A
27A