BL.O.Gobo Moving
—
Blackout while Gobo moving
To select
BL.O. Gobo Moving
, press the
ENTER
button to confirm. Use the
UP
/
DOWN
button to
select
No
(normal while gobo moving) or
Yes
(blackout while gobo moving), press the
ENTER
button to store. Press the
MENU
button back to the last menu or let the unit idle one minute to
exit menu mode.
Dimmer Curve
To select
Dimmer Curve
, press the
ENTER
button to show the
DIMMER CURVE
on the display. Use
the
DOWN
/
UP
button to select the
Mode1
or
Mode 2
or
Mode 3
or
Mode 4
. Once the mode has
been selected, press the
ENTER
button to setup, to go back to the functions without any change
press the
MENU
button again. Press and hold the
MENU
button about one second or wait for one
minute to exit the menu mode.
Mode 1(Optically Linear):
The increase in light intensity appears to be linear as DMX value is increased.
Mode 2(Square Law):
Light intensity control is finer at low levels and coarser at high levels.
Mode 3(Inverse Square Law):
Light intensity control is coarser at low levels and finger at high levels.
Mode 4(S-cure):
Light intensity control is finger at low levels and high levels and coarser at medium levels.
Soft Filter
To select
Soft Filter
, press the
ENTER
button to confirm. Use the
UP
/
DOWN
button to select
Auto
,
Disable
or
Enable
, press the
ENTER
button to store. Press the
MENU
button back to the last menu
or let the unit idle one minute to exit menu mode.