XP-5R Beam
-
25
-
6.4. Error Information
Lamp Startup Fail
It appears when there is no lamp or some wires are damaged.
Temperature Sense Error
It appears when temperature check board is damaged.
Lamp Too Hot Power Off
It appears when temperature is detected higher than 110
℃
. Check if the unit is properly
ventilated, or fans or temperature check board may is damaged.
Lamp Too Hot Low Power
It appears when temperature is detected higher than 105
℃
. the unit will run on a low power
level.
Maintenance Fixture
It appears when the maintenance remaining time becomes 0S, please enter menu mode
and reset the time.
Lamp On Over 700 Hour
It appears when the lamp has been on over 700 hours, please turn off the lamp.
Memory Initial Fail
It appears when the memory IC is damaged.
CPU-B Error, CPU-C Error, CPU-D Error
They appear when board P.C or some wires are damaged.
Pan Reset Error, Pan Encode Error, Tilt Reset Error, Tilt Encode Error, Shutter Reset
Fail, Dimmer Reset Fail, Color Reset Fail, , Gobo Reset Fail, , , and Frost Reset Fail
They may appear when turning on or resetting the unit, for some parts such as board P.C
are damaged. Please contact the qualified maintenance.
14-
DMX Functions
Enter menu mode, select
DMX Functions
, press ENTER button to confirm, use UP
and DOWN button to select
DMX Address, DMX Channel Mode
or
View DMX Value
DMX Address
—
DMX512 address setting
Select
DMX Address
, press ENTER button to confirm, the present address will blink on
the display, use UP and DOWN button to adjust the address from
1
to
512
, press
ENTER button to store. Press MENU button back to the last menu or let the unit idle
one minute to exit menu mode.
DMX Channel Mode
—
channel mode
Select
DMX Channel Mode
, press ENTER button to confirm, present channel mode