User's Manual | ACOM 500S | 160-4
m Linear Power Amplifier
March 2023
S e c t i o n INSTALLATION | Page 23 of 66
g)
Main fuses
Figure 2-3 | Rear panel - Connections
, Pos. (g).
NOTICE
Make sure you check whether the main fuses installed in your amplifier correspond to
your local mains nominal voltage. If occasion should require replacement of the mains
fuses, replace them as described in Section
h)
Power cord
Figure 2-3 | Rear panel - Connections
, Pos. (h).
Due to the different standards in different countries, the mains plug is supplied and mounted by the dealer.
He connects to the mains cord end a standard mains supply plug which meets the Safety Class I unit standard
in your country. The ground lead of the amplifier's power cord is colored yellow with two green stripes and
the blue and brown leads are active. When the amplifier is to be used with only one mains fuse, it is
connected in series with the brown lead, which must be the active. If you have any doubts about the correct
way of connecting the wires, consult your dealer.
i)
Preparation of wall outlet
WARNING
Before connecting the amplifier to your mains supply using a licensed electrician, check
that the supply is correctly wired, and is adequate for the current drawn by the amplifier
(up to 6.3 A from 200/240 VAC mains and up to 12 A from 100/120 VAC mains). Make
certain that the grounding lead is connected properly and that it has a cross section not
less than the cross section of the phase conductor in the wall outlet for the amplifier.
It is preferable that you use the wall outlet closest to the source. The installation leads should be at least
1.5
mm² (AWG 15 or
SWG 17) at operating 200-240
VAC and 2.5 mm² (AWG 13 or SWG 15) at 100
-120 VAC
(recommended values if there are no stricter requirements by your local standard). Check that the panel fuse
has a free capacity for the additional load from the amplifier as specified in Section Specifications
Power Consumption at Rated Output Power
If you connect the amplifier to a different mains outlet, be sure
that you check it, too.
Make sure the Main Power Switch (marked
ON
/
OFF
, see
Figure 2-3 | Rear panel - Connections
, Pos. (1)), on the
rear panel is in
OFF
position and insert amplifier's mains plug into the wall outlet prepared for it. The amplifier
remains switched off.