common trouble-shooting

Troubles

trouble shooting

solution

When the modules 

directly face to the sun ,the 

charge indicator does not 

light

1

solar arrays’

connection open

2

solar cells connected

reverse

1

Check the power terminals if in correct and 

good connection,

2

Controller may be damaged,change a new one

Charging light fast

flashing

Voltage turn off

when battery voltage is 

in overpressure,

Measuring the battery voltage if it is too high,then 

disconnect the modules

LED1 :Led1 fast 

flashing

      Battery over discharge

The controller output shut down automatically , 

indicator light in normal flash when the battery is full of 

charge

Load Leds slow 

flashing

Load power exceeds 

rated power

Reduce some AC loads and press the button 3 

seconds to recover the controller output

Load Leds fast flashing

Load :short-circuit

When short-circuit happened in the first time, 

please wait 10 seconds,the system

output shall be auto restart or you can press the 

button 3 seconds to get the normal output; if 

short-circuit take place one after another , the system 

output will return to normal only by pressing the 

button 3 seconds

indicator is off    on 

the normal charging status

Input power is less than the 

battery power

Measure the controller input voltage which must 

be higher than the battery voltage

www.ACOPower.com

Power Your Green Life!

105W Foldable solar panel

Summary of Contents for 3x35W

Page 1: ...One pair of the alligator clips is for connecting the battery red for anode black for cathode 3 Be used for fixed the unfolding solar panels 4 To control the output and protect the modules 5 unfolded...

Page 2: ...indicator LED1 LED2 LED3 will flash accordingly 6 Press the button again to set up the exact battery type after the selection stop button operation 5 seconds no flashing lights means complete the set...

Page 3: ...output load load indicator light 2 when the load current exceeds 1 25 times the rated load current of 60 seconds and 1 5 times the rated load current of 5 seconds overload when the load indicator flas...

Page 4: ...up stand for extinguish Ubat stand for battey voltage Battery indicator voltage parameters are 25 12Vsystem parameters 24V system parameters x2 Load switch setting method When the controller is in nor...

Page 5: ...ight in normal flash when the battery is full of charge Load Leds slow flashing Load power exceeds rated power Reduce some AC loads and press the button 3 seconds to recover the controller output Load...

Page 6: ...pe the surface of solar modules to remove the remaining dust and dirt Recommend any guano adhesive should be removed as soon as possible from the surface of solar modules so as not to affect performan...

Page 7: ...and refund Remedy but fuse excluded Force Majeure Sungols shall not be responsible or liable in any way to the customer or any third party arising from any non performance or delay in performance of a...

Reviews: