www.ACOPower.com
4120 Valley Blvd Walnut, CA 91789, USA
+1-626-737 1140
HY-PTK-100WPX20A
Voltage in below table are for 12V use, x 2 for 24V use.
6 Technical Specifications
--Li-ion battery
12.6
+/-0.2
VDC
2-6
Absorption transits to Equalizing or Float condition:
--Charging current drops to
1.5
+/0.1
AMP
-- or Absorption charging timer timed out
4
Hour
2-7
Equalization charging active
--Only for WET or Calcium battery
--Battery voltage discharged to less than
10
+/-0.2
VDC
--Automatic equalizing charging periodical
28
Day
2-8
Equalization charging voltage at 25
℃
15.5
+/-0.2
VDC
2-9
Equalization charging timer timed out
2
Hour
2-10
Float voltage (for Crystal, GEL, WET, Calcium, AGM battery) at 25
℃
13.8
+/-0.2
VDC
Restart voltage for LTO battery
13.2
+/-0.2
VDC
Restart voltage for LFP battery
13.4
+/-0.2
VDC
Restart voltage for Li-ion battery
12.0
+/-0.2
VDC
2-11
Voltage control accuracy
+/- 1%
2-12
Battery temperature compensation coefficient
-24
mV/*C
2-13
Temperature compensation range
-20 ~ +50
℃
3
Protection
3-1
Against reverse polarity or short circuit at panel or battery
3-2
No reverse current from battery to solar at night
3-3
Over temperature protection during charging
65
℃
4
Electrical parts
4-1
Input output terminal
M5 terminals
5
Physical Parameters
5-1
Controller material
Plastic, Standard ABS
5-2
Power terminal maximum stranded wire size
#6 AWG stranded-16 mm
2
5-3
Power terminal torque
Up to 17 in-lb (0.2n-m)
5-4
Mounting
Vertical wall mounting
5-5
IP grade
IP65,
5-6
Net weight
Approx. 0.5KG
6
Environmental characteristics
6-1
Operating temperature
-25 ~ 50
℃
/ -13~122
℉
6-2
Storage temperature
-40 ~ 85
℃
/ -40~185
℉
6-3
Operating Humidity range
100% no condensation