www.ACOPower.com
4120 Valley Blvd Walnut, CA 91789, USA
+1-626-737 1140
HY-PTK-100WPX20A
3 SAFETY PROTECTION -
-Spark-free protection.
-Reverse polarity solar and battery connection.
-Against reverse current from battery to solar panel at night.
-Over temperature protection with charging current de-rate.
-Transient overvoltage protection, a varistor or transient voltage suppressor (TVS) at the solar input and battery
output against surge voltage.
-Safety and EMC compliance
IEC/EN 60335, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5 FCC Class-B
EN61000-4-6, EN61000-4-11, EN61000-3-3, CISPR14-1
4 MAINTENANCE-
Occasionally, clean the case using a damp cloth and mild cleaning agent. Check with terminals without loose, rus
ty; If connecting cable is damaged, replace the cable by qualified person.
5 SPECIFICATION-
Voltage in below table are for 12V use, x 2 for 24V use.
1
Electrical Parameters
1-1
Rated solar panel amps
10/15/20
Max.
AMP
1-2
Normal input Solar cell array voltage
15-22
VDC
1-3
Max. solar cell array voltage (output has no load)
25
Max.
VDC
1-4
The controller lowest operating voltage at solar or battery side
8V
Min
VDC
1-5
Standby current consumption at night
5
Max
mA
1-6
Maximum voltage drop-Solar panel to battery
0.25
Max.
VDC
2
Charging characteristics
2-1
Minimum battery start charging voltage
3
Min
VDC
2-2
Soft start charging voltage
3-10
+/-0.2
VDC
2-3
Soft start charging current (50% PWM duty)
Up to 5/7.5/10
AMP
2-4
Bulk charge
By the maximum rated current
Bulk charge level1 for Lead Crystal battery
By 100% maximum rated current charge
up to 14.4V.
Bulk charge level2 for Lead Crystal battery
By 50% rated current charge up to 14.7V
from 14.4V.
2-5
Absorption charging voltage at 25
℃
--Lead Crystal battery
14.7
+/-0.2
VDC
--Gel type battery
14.1
+/-0.2
VDC
--AGM type battery (default setting)
14.4
+/-0.2
VDC
--WET type battery
14.7
+/-0.2
VDC
--Calcium type battery
14.9
+/-0.2
VDC
--LTO battery
14.0
+/-0.2
VDC
--LFP battery
14.5
+/-0.2
VDC