34
Troubleshooting
Standby Condition
Blower motor operates?
Inoperative blower motor.
Inoperative auto-transformer.
Broken or improper wire connections.
1.
2.
3.
"Standby Condition" normal - proceed to
"Cook Condition".
Yes
Yes
Open oven door.
Oven light is on?
Antenna motor(s) operate?
Inoperative light bulb.
Inoperative light socket.
Inoperative auto-transformer.
Broken or improper wire connections.
1.
2.
3.
4.
Inoperative antenna motor.
Binding gears (bottom antenna only).
Inoperative auto-transformer.
Broken or improper wire connections.
1.
2.
4.
5.
Inoperative interlock switch assembly (logic or primary).
Inoperative control board.
Broken or improper wire connections.
1.
2.
3.
NO
Inoperative control board.
5.
NO
NO
NO
Yes
Yes
Display
Grease shield installed upside down
(top antenna only).
3.