23
1.5.3 Test Run Method
The inverter can be operated in the following two ways .The model with digital operator is set to
“OPERATION MODE BY DIGITAL OPERATOR” and the model with analog operator (JNEP--14) is set
to “OPERATION MODE FROM CONTROL CIRCUIT TERMINAL” prior to shipping.
This method is to operate the inverter by
using the RUN (run command) key, etc. of
the digital operator.
Since this operation mode is set at the
factory prior to shipping, operation can be
performed only by main circuit wiring.
For details of the operation method, refer
to Section 2 beginning on page 43.
This method is to operate the inverter by
frequency setter or operation switch
connected to the control circuit terminal.
To perform operation by control circuit
terminal input of the model with digital
operator, change the operation mode to
“ OPERATION FROM CONTROL
CIRCUIT TERMINAL”
(Pn-01=0000).
JNEP--14
7200M3
JNEP--13
7200M3
Run by digital operator
(Standard setting of model
with digital operator )
Run by control circuit terminal
input ( Standard Setting of
model with analog operator)
POWER
IM
POWE
IM