50
2.1.2 Constant Reading and Setting
The 7200M3 has various functions for the optimum operation. The A group functions are those basic to
drive motors. The B group are for basic applications. The C group are more advanced application
functions. Use it with the set values according to the load conditions or operation conditions of the
matching machine. Control constants are read or set by the digital operator. Set constant (Pn-00) as
follows:
Setting Value
Description
Note
0 A group function (Pn-01~19) can not be set
Lock mode
1 A group function (Pn-00~19) can be set/read
Factory
Setting
2 A, B group function (Pn-00~29) can be set/read
—
Pn-00=
3 A, B, C group function (Pn-00~59) can be set/read —