4.2 Error Code
①
. If abnormal things (for example, awful smell) occur, please stop the unit
immediately and disconnect power. Then contact
AC PRO
’s authorized service
center. If the unit continues to run in abnormal situations, it may get damaged and
cause electric shock or fire hazard.
②
. Do not repair the air conditioner by yourself. Improper maintenance will cause
electric shock or fire hazard. Please contact
AC PRO
’s authorized service center and
send for professional service staff to repair.
If the LED displayer on mainboard of outdoor unit displays an error code, please
refer to the error code meaning stated in the following table.
No.
Error code
Error
1
E1
Compressor high pressure protection
2
E3
Compressor low pressure protection
3
E4
Compressor air discharge high-temperature protection
4
F2
Condenser temperature sensor error
5
F3
Outdoor ambient temperature sensor error
6
F4
Discharge temperature sensor error
7
F6
ODU tube temperature sensor error
8
EE
ODU memory chip error
9
H4
Overload
10
H5
IPM protection
11
H6
DC fan error
12
H7
Driver out-of-step protection
13
HC
Pfc protection
14
Lc
Startup failure
15
P0
Driver reset protection
16
P5
Over-current protection
17
P6
Master control and driver communication error
18
P7
Driver module sensor error
19
P8
Driver module high temperature protection
20
PA
AC current protection
21
Pc
Driver current error
22
PL
Bus low-voltage protection
23
PH
Bus high-voltage protection
24
PU
Charge loop error
25
ee