background image

18 

19 

Programming the Timer 

 

• 

Press TIMER

TIMER

TIMER

TIMER until P1

P1

P1

P1

 flashes (period 1, heating cycle on). 

• 

Set  the  time  for  the  beginning  of  he  first  heating  period  by  pressing  (

)  for  hour 

and (

) for minute. 

• 

Press TIMER

TIMER

TIMER

TIMER again; and P1

P1

P1

P1

 appears. 

• 

Set the timer for end of the first heating period. 

• 

Press TIMER

TIMER

TIMER

TIMER again to set the second heating period P2

P2

P2

P2

    (heat off).

 

 

• 

Store both heating periods by pressing TIMER

TIMER

TIMER

TIMER again. 

• 

If only one heating period is desired, program the same time for P2

 and P2

 as for 

P1

 and P1

 

Manual Mode (MAN in display) for Manual Flame Height Adjustment 
 

• 

Press (

) to turn on the fire (main burner) or to increase flame height. 

• 

Press (

) to decrease flame or to turn down to pilot. 

• 

To incrementally increase or decrease the flame height, lightly tap either the (

) or (

button. 

• 

The  send

send

send

send symbol  appears  in the upper  left corner  of  the  display when either  large 

button is depressed. 

• 

The LED of the receiver flashes when knob B of the valve reaches the end stops. 

 

Automatic Mode (Auto in display) for Temperature Control 

 

• 

Briefly press AUTO

AUTO

AUTO

AUTO. The set temperature will appear briefly before the display reverts to 

the room temperature. 

 

Timer Mode (Timer in Display) 

 

• 

During  heating  periods  P1

P1

P1

P1

  and  P2

P2

P2

P2

  the  temperature  is  controlled  in  the  same 

manner as in automatic mode. 

• 

When the timer program turns to 

 (heating cycle off), the motor will then valve to pilot 

and there is no temperature control. This minimises battery consumption. 

• 

You may press  AUTO

AUTO

AUTO

AUTO to verify the set temperature and then press  TIMER

TIMER

TIMER

TIMER to return to 

timer mode. 

• 

You may press either the (

) or (

) button from any mode for manual override. 

• 

To prolong battery  life, we recommend switching the transmitter to manual mode and 
turning  the  fire  to  pilot  with  the  (

)  button  before  turning  the  appliance  off.  If  the 

transmitter is left in automatic or timer mode, the batteries will continue to be used when 
the appliance is off. 

 

Changing the Battery 

 

• 

If  BATT

BATT

BATT

BATT appears in upper right hand corner of the display or if the LED of the receiver 

becomes  faint,  please  change  the  battery  from  transmitter  or  receiver.  If  the  batteries 
lose power, the flame height can be adjusted by manually turning Knob B. 

 

 

DATA INFORMATION 

  

  
  
  
  
  
  
  
  
  
  
  
  

The temperature is controlled by activating the motor for a specific length of time to adjust the 
appropriate  flame height. The  time  is calculated by  the transmitter and depends on variables 
such as room size, heater capacity, battery power, etc. 
Therefore,  a  few  cycles  are  necessary  before  optimum  is  achieved.  If  a  low  flame  is 
sufficient to provide enough warmth to the room, then the appliance will cycle between low 
fire and off. 
This allows longer periods with the flame on and provides a more uniform room temperature. 
 
 
 
 

  
  
  
  
  

  

The stove is fitted with a spillage monitoring system which senses any excess temperature 
due to a flue restriction or blockage. In this event the gas supply is automatically turned off. 
Should this occur turn the control knob to the OFF

OFF

OFF

OFF position and wait approximately 10 minutes 

for  the  switch  to  automatically  reset.  Re-light  the  stove  as  described  in  OPERATING  THE 
STOVE section (page 15). If the stove repeatedly shuts itself off, DO NOT 

DO NOT 

DO NOT 

DO NOT use the stove and 

have the flue system checked by a qualified person. 
The spillage monitoring system is not adjustable and must not be put out of action  

  
  
  

Ensure that the stove is turned off before cleaning and is cold.  
DO NOT 

DO NOT 

DO NOT 

DO NOT use abrasive cleaning agents.  
The stove is supplied with ceramic coal that should only be cleaned and arranged by a 
qualified person in accordance with the Installation Instructions.  

  
  
  

The Data Label is located at the rear of the stove. 

 

 

  

  
It is essential that the stove is regularly serviced, and the flue system checked by a qualified 
person.  

SPILLAGE MONITORING SYSTEM 

CLEANING 

SERVICING 

Please note, the placement of the transmitter (temperature sensor) is important to 
assure  proper  temperature  regulation.  Generally,  a  more  constant  temperature 
will be assured, if the transmitter is not too far from the gas appliance. Before 
switching  to  AUTO

AUTO

AUTO

AUTO  or  TIMER

TIMER

TIMER

TIMER  Mode,  press  either  button  (

)  or  (

)  to  verify 

the reception (when the send symbol appears in the  transmitter display, the 
receiver’s  LED  must  illuminate).  For  the  AUTO

AUTO

AUTO

AUTO  or  TIMER

TIMER

TIMER

TIMER  mode  to  function 

correctly, the transmitter must remain within range of the receiver. The transmitter 
should not be used in very close proximity to the receiver (less than 1m/3ft) 
as  this  could  block  the  motor  when  the  knob  reaches  the  end  points  of  its 
turning radius. The knob must then be turned manually to free the blockage.

 

It is recommended to turn the combination control either to the OFF

OFF

OFF

OFF or PILOT

PILOT

PILOT

PILOT 

position  if  the  appliance  is  left  unattended  for  longer  periods  (i.e.  away),  so 
that  it  cannot  receive  commands  from  the  remote  transmitter.  Exercise  caution 
when  leaving  the  appliance  unattended,  in  exceptional  cases  sound  waves 
from  sources  other  than  the  transmitter  can  cause  changes  in  flame  height 
adjustment. 

Summary of Contents for BLOOMSBURY

Page 1: ...R INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER UK IRELAND GB IE 9 11 PP Acquisitions Fireplaces Ltd Acquisitions House 24 26 Holmes Road London NW5 3AB Tel 020 7482 2949 Fax 020 7267 4361 e mail sales acquisitions co uk www acquisitions co uk Manufactured for Acquisitions by Esse Engineering Ltd ...

Page 2: ...shall only be fitted in accordance with National Regulations If the chimney has previously been used to burn solid fuel the chimney should be swept before the stove is installed Before the stove is installed a flue test in accordance with National Regulations should be carried out The gas connection must be in accordance with National Regulations The stove is fitted with a spillage monitoring syst...

Page 3: ...m a combustible material Flue Connection The flue should be at least 3m high and at least 125mm diameter or equivalent area Horizontal or negative gradients in the flue pipe should be avoided It is recommended that a minimum height of 610mm from the stove should be established before any significant change in the direction of the flue An optional rear flue attachment is available as an accessory f...

Page 4: ...urn clockwise to PILOT PILOT PILOT PILOT position Disconnect the pressure gauge replace the test point sealing screw and test for gas soundness Turning the Pilot OFF From any heat setting or the PILOT PILOT PILOT PILOT position depress control knob fully and turn clockwise to OFF OFF OFF OFF position 7 Fig 4 Control Knob Manual Remote Controlled Stoves This stove has a pilot that must be lit manua...

Page 5: ... necessary Disconnect the pressure gauge tighten the test point sealing screw and test for gas soundness 9 HANDSET OPERATION HANDSET OPERATION HANDSET OPERATION HANDSET OPERATION refer to Fig 6 Programming the Desired Set Temperature Press AUTO AUTO AUTO AUTO until the display flashes Press or to set desired temperature Wait or press AUTO AUTO AUTO AUTO to switch to automatic mode A sensor in the ...

Page 6: ...e we recommend switching the transmitter to manual mode and turning the fire to pilot with the button before turning the appliance off If the transmitter is left in automatic or timer mode the batteries will continue to be used when the appliance is off Changing the Battery If BATT BATT BATT BATT appears in upper right hand corner of the display or if the LED of the receiver becomes faint please c...

Page 7: ...quite normal and will not affect the safe operation of the fire Replace the front coal piece back board and coals as described in the POSITIONING THE COALS section page 5 6 Close the stove door replace the screw securing the door handle or door 7 Check the supply pressure as described in the COMMISSIONING THE STOVE section page 6 8 Ensure correct operation of the flue as described in CHECK FOR SPI...

Page 8: ...ied DO NOT DO NOT DO NOT DO NOT use any extra logs or coal MANUALLY OPERATED STOVES The stove is fitted with a pilot light piezo spark and flame sensing device The control knob is located behind the right hand foot of the stove The pilot light is located centrally behind the front coal piece Should the stove be extinguished for any reason wait 3 minutes before re ignition is attempted The stove sh...

Page 9: ...de A sensor in the transmitter measures the room temperature The controller compares the room temperature with the set temperature and sends a signal to the receiver to turn the gas valve motor which adjusts the flame height accordingly Fig 11 Remote Transmitter REMOTE CONTROLLED STOVES This stove has a pilot that must be lit manually When lighting the pilot follow these instructions exactly Light...

Page 10: ...ariables such as room size heater capacity battery power etc Therefore a few cycles are necessary before optimum is achieved If a low flame is sufficient to provide enough warmth to the room then the appliance will cycle between low fire and off This allows longer periods with the flame on and provides a more uniform room temperature The stove is fitted with a spillage monitoring system which sens...

Reviews: