COMMISSIONING THE STOVE
Manually Operated Stoves
The stove is fitted with a pilot light, piezo spark and flame sensing device.
The control knob is located behind the right-hand foot of the stove.
The pilot light is centrally located behind the front coal piece.
Should the stove be extinguished for any reason wait 3 minutes before re-ignition is
attempted.
Connect a suitable pressure gauge to the pressure test point.
Lighting the Pilot
Depress control knob fully. Whilst depressed turn knob slowly through 90
°
anti-clockwise
to PILOT
PILOT
PILOT
PILOT setting. A click will be heard and the piezo spark should light the pilot. Repeat
until pilot is visibly lit. If necessary, the operation of the spark can be viewed by
temporarily opening the front door.
Keep knob depressed at this point for 10-15 seconds and release the knob. The pilot
light will remain lit.
Low Setting
If the Pilot light is not already lit, light the pilot as described above.
With the control knob at PILOT
PILOT
PILOT
PILOT setting, depress and turn anti-clockwise to LOW
LOW
LOW
LOW setting
and release the knob.
High Setting
If the stove is not already lit on LOW
LOW
LOW
LOW setting, ignite stove to LOW
LOW
LOW
LOW setting as described
above.
Turn the control knob anti-clockwise until HIGH
HIGH
HIGH
HIGH setting is reached. Check that the
supply pressure and/or setting pressure is in accordance with that given in the
TECHNICAL INFORMATION section.
Turning the Stove OFF
From any heat setting, depress control knob fully and turn clockwise to PILOT
PILOT
PILOT
PILOT position.
Disconnect the pressure gauge, replace the test point sealing screw and test for gas
soundness.
Turning the Pilot OFF
From any heat setting or the PILOT
PILOT
PILOT
PILOT position, depress control knob fully and turn
clockwise to OFF
OFF
OFF
OFF position.
7
Fig 4 - Control Knob (Manual)
Remote Controlled Stoves
This stove has a pilot that must be lit manually. When lighting the pilot, follow these
instructions exactly.
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS (refer to Fig. 5)
Should the stove be extinguished for any reason wait 3 minutes before ignition is attempted.
Slacken the left hand pressure test sealing screw on the gas valve (Fig. 5) and connect a
suitable pressure gauge.
Lighting the Pilot
Turn Knob A (Fig. 5) anti-clockwise towards the ignition position (IGN
IGN
IGN
IGN) until reaching
stop, press down and hold for five seconds (only pilot gas flows).
Continue pressing down Knob A while turning further anti-clockwise to activate
piezo; continue to hold down for 10 seconds after pilot burner has been lit. If pilot does
not light, steps 1 and 2 can be repeated immediately.
Upon lighting, release knob and turn further anti-clockwise to ON
ON
ON
ON position. Pilot gas
flows and main gas flows in accordance to the temperature setting knob B.
High Setting
If the pilot is not already lit, light the pilot as described above.
Turn knob B anti-clockwise until the high setting is reached. Check the setting pressure
is in accordance with that given in the TECHNICAL INFORMATION section (page 2).
Adjust if necessary (Fig. 5).
Knob A cannot be turned from ‘PILOT’ to ‘OFF’ unless it is pushed in slightly.
Do not force.
6