background image

COMMISSIONING THE STOVE 

 

Manually Operated Stoves 

 
The stove is fitted with a pilot light, piezo spark and flame sensing device. 

The control knob is located behind the right-hand foot of the stove. 
The pilot light is centrally located behind the front coal piece. 

Should  the  stove  be  extinguished  for  any  reason  wait  3  minutes  before  re-ignition  is 
attempted. 
Connect a suitable pressure gauge to the pressure test point. 

 

Lighting the Pilot 

Depress control knob fully. Whilst depressed turn knob slowly through 90

°

 anti-clockwise 

to PILOT

PILOT

PILOT

PILOT setting. A click will be heard and the piezo spark should light the pilot. Repeat 

until  pilot  is  visibly  lit.  If  necessary,  the  operation  of  the  spark  can  be  viewed  by 
temporarily opening the front door. 

Keep knob depressed at this point for 10-15 seconds and release the knob. The pilot 
light will remain lit. 

 

Low Setting 

If the Pilot light is not already lit, light the pilot as described above. 

With the control knob at PILOT

PILOT

PILOT

PILOT setting, depress and turn anti-clockwise to LOW

LOW

LOW

LOW setting 

and release the knob. 

 

High Setting 

If the stove is not already lit on  LOW

LOW

LOW

LOW setting, ignite stove to  LOW

LOW

LOW

LOW setting as described 

above. 
Turn  the  control  knob  anti-clockwise  until  HIGH

HIGH

HIGH

HIGH  setting  is  reached.  Check  that  the 

supply  pressure  and/or  setting  pressure  is  in  accordance  with  that  given  in  the 
TECHNICAL INFORMATION section. 

 

Turning the Stove OFF 

From any heat setting, depress control knob fully and turn clockwise to PILOT

PILOT

PILOT

PILOT position. 

Disconnect  the  pressure  gauge,  replace  the  test  point  sealing  screw  and  test  for  gas 
soundness. 

 

Turning the Pilot OFF 

From  any  heat  setting  or  the  PILOT

PILOT

PILOT

PILOT  position,  depress  control  knob  fully  and  turn 

clockwise to OFF

OFF

OFF

OFF position. 

 
 

 

 

Fig 4 - Control Knob (Manual) 
 
 
 
 
 
 
 
 
 
 
 
 
 
Remote Controlled Stoves  
 

This  stove  has  a  pilot  that  must  be  lit  manually.  When  lighting  the  pilot,  follow  these 
instructions exactly. 

  
LIGHTING INSTRUCTIONS 

LIGHTING INSTRUCTIONS 

LIGHTING INSTRUCTIONS 

LIGHTING INSTRUCTIONS (refer to Fig. 5) 

 
Should  the  stove  be  extinguished  for  any  reason  wait  3  minutes  before  ignition  is  attempted. 
Slacken the left hand pressure test sealing screw on the gas valve (Fig. 5) and connect a 
suitable pressure gauge. 

 

 

 

Lighting the Pilot 

Turn  Knob  A  (Fig.  5)  anti-clockwise  towards  the  ignition  position  (IGN

IGN

IGN

IGN)  until  reaching 

stop, press down and hold for five seconds (only pilot gas flows). 

Continue  pressing  down  Knob  A  while  turning  further  anti-clockwise  to  activate 
piezo; continue to hold down for 10 seconds after pilot burner has been lit. If pilot does 
not light, steps 1 and 2 can be repeated immediately. 
Upon  lighting,  release  knob  and  turn  further  anti-clockwise  to  ON

ON

ON

ON  position.  Pilot  gas 

flows and main gas flows in accordance to the temperature setting knob B. 

 

High Setting 

If the pilot is not already lit, light the pilot as described above. 
Turn knob B anti-clockwise until the high setting is reached. Check the setting pressure 
is  in  accordance  with  that  given  in  the  TECHNICAL  INFORMATION  section  (page  2). 
Adjust if necessary (Fig. 5). 

Knob A cannot be turned from ‘PILOT’ to ‘OFF’ unless it is pushed in slightly. 

Do not force. 

Summary of Contents for BLOOMSBURY

Page 1: ...R INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER UK IRELAND GB IE 9 11 PP Acquisitions Fireplaces Ltd Acquisitions House 24 26 Holmes Road London NW5 3AB Tel 020 7482 2949 Fax 020 7267 4361 e mail sales acquisitions co uk www acquisitions co uk Manufactured for Acquisitions by Esse Engineering Ltd ...

Page 2: ...shall only be fitted in accordance with National Regulations If the chimney has previously been used to burn solid fuel the chimney should be swept before the stove is installed Before the stove is installed a flue test in accordance with National Regulations should be carried out The gas connection must be in accordance with National Regulations The stove is fitted with a spillage monitoring syst...

Page 3: ...m a combustible material Flue Connection The flue should be at least 3m high and at least 125mm diameter or equivalent area Horizontal or negative gradients in the flue pipe should be avoided It is recommended that a minimum height of 610mm from the stove should be established before any significant change in the direction of the flue An optional rear flue attachment is available as an accessory f...

Page 4: ...urn clockwise to PILOT PILOT PILOT PILOT position Disconnect the pressure gauge replace the test point sealing screw and test for gas soundness Turning the Pilot OFF From any heat setting or the PILOT PILOT PILOT PILOT position depress control knob fully and turn clockwise to OFF OFF OFF OFF position 7 Fig 4 Control Knob Manual Remote Controlled Stoves This stove has a pilot that must be lit manua...

Page 5: ... necessary Disconnect the pressure gauge tighten the test point sealing screw and test for gas soundness 9 HANDSET OPERATION HANDSET OPERATION HANDSET OPERATION HANDSET OPERATION refer to Fig 6 Programming the Desired Set Temperature Press AUTO AUTO AUTO AUTO until the display flashes Press or to set desired temperature Wait or press AUTO AUTO AUTO AUTO to switch to automatic mode A sensor in the ...

Page 6: ...e we recommend switching the transmitter to manual mode and turning the fire to pilot with the button before turning the appliance off If the transmitter is left in automatic or timer mode the batteries will continue to be used when the appliance is off Changing the Battery If BATT BATT BATT BATT appears in upper right hand corner of the display or if the LED of the receiver becomes faint please c...

Page 7: ...quite normal and will not affect the safe operation of the fire Replace the front coal piece back board and coals as described in the POSITIONING THE COALS section page 5 6 Close the stove door replace the screw securing the door handle or door 7 Check the supply pressure as described in the COMMISSIONING THE STOVE section page 6 8 Ensure correct operation of the flue as described in CHECK FOR SPI...

Page 8: ...ied DO NOT DO NOT DO NOT DO NOT use any extra logs or coal MANUALLY OPERATED STOVES The stove is fitted with a pilot light piezo spark and flame sensing device The control knob is located behind the right hand foot of the stove The pilot light is located centrally behind the front coal piece Should the stove be extinguished for any reason wait 3 minutes before re ignition is attempted The stove sh...

Page 9: ...de A sensor in the transmitter measures the room temperature The controller compares the room temperature with the set temperature and sends a signal to the receiver to turn the gas valve motor which adjusts the flame height accordingly Fig 11 Remote Transmitter REMOTE CONTROLLED STOVES This stove has a pilot that must be lit manually When lighting the pilot follow these instructions exactly Light...

Page 10: ...ariables such as room size heater capacity battery power etc Therefore a few cycles are necessary before optimum is achieved If a low flame is sufficient to provide enough warmth to the room then the appliance will cycle between low fire and off This allows longer periods with the flame on and provides a more uniform room temperature The stove is fitted with a spillage monitoring system which sens...