Page 23
AB-G200L-REM-I01-150914
SPILLAGE MONITORING SYSTEM
The stove is fitted with a spillage monitoring system which senses any excess
temperature due to a flue restriction or blockage. In this event the gas supply is
automatically turned off.
Should this occur then slide the Fire control unit isolator switch to
OFF (0)
position and
wait approximately 10 minutes for the switch to automatically reset. Re-light the stove
as described in OPERATING THE STOVE section (page 15). If the stove repeatedly shuts
itself off, DO NOT use the stove and have the flue system checked by a qualified person.
This spillage monitoring system is not adjustable and must not be put out of action.
ERROR CODES
The Control unit is NOT faulty just because its shows an Error code. The Error code can
be read when a wireless Control unit is paired with a Wireless enabled Remote control.
The Error Code is there to enable servicing to identify what may be happening to the
Control unit to cause the fire not to operate correctly. This is most likely to be
environmental or one of the other components that are connected to the Control unit.
If an E code is displayed, allow the fire to cool and perform a normal start attempt to
reset the control to standby. Then perform a normal start attempt again to see if the
fire has cleared the error and the fire is functioning correctly.
If the ERROR does not clear, it is essential before undertaking any actions on the
servicing as detailed below, that the batteries being used are good and should be
replaced with new ones to be sure that is not the problem. Faulty batteries can cause
false error codes. New batteries can be faulty too. ALWAYS CHANGE ALL THE
BATTERIES TOGETHER AND NOT JUST ONE OR TWO AND ALWAYS OF THE SAME MAKE
AND TYPE (I.E MANUFACTURER AND MODEL TYPE).
The battery contact must be clean and there must not be any leakage from any batteries
in the battery compartment or on the battery contacts. Clean thoroughly if found, they
must be spotlessly clean.
After replacing the batteries, to clear the error code perform a start cycle by pressing
the start button as normal. Then press again in the same way to attempt a new start
cycle. The error code must be cleared for the fire to function correctly.
Servicing must only be carried out by competent personal that have current
qualifications and accreditation (i.e. Gas safe).