background image

Removing the

Glass Assembly

X-FIRE 1200

Ensure the X-FIRE 1200 is allowed to cool before continuing with the following
procedure.

Pull the four hooks shown below towards you and then away from the glass
to release the glass frame underneath the hook.

Lift the glass assembly towards you to clear the locating supports and
place it flat upon some newspaper or a sheet of cardboard to protect your
floor coverings.

Cleaning and Maintenance

8

Removing the

Fascia

X-FIRE 1200

To replace the fascia, line up the four hooks with the matching receptacles on
the fire and push the fascia into place and let it drop down, the fascia should
now be securely in position

The X-FIRE 1200 fascia attaches to the fire by four hooks. To remove the
fascia, simply lift it upwards 15-20mm, and pull towards you. Care should
always be taken when handling the fascia.

Ensure the fascia is allowed to cool before handling.

Annual Servicing

Your X-FIRE 1200 Decorative Gas Fireplace requires that annual service
checks be carried out by a Registered Installer to ensure that it will continue to
operate in a safe manner.

Please ensure that you schedule annual service checks for your X-FIRE 1200
with your local Registered Installer or service agent.

X-FIRE 1200

Summary of Contents for X-FIRE 1200

Page 1: ...20 at a supply pressure of 20 mbar or Propane G31 at a supply pressure of 37 mbar USER GUIDE DISTRIBUTED BY Acquisitions of London 24 26 Holmes Road London Nw5 3AB 630142_1 GB IE EDITION Tel 24 hours 004 0 207 482 2949 Email sales acquisitions co uk LEAVE WITH USER ...

Page 2: ...IED IN PAGE 7 OFTHIS USER MANUAL THE NOx LEVEL OF THIS APPLIANCE IS 85 mg kWh WITH NATURAL GAS G20 AND COALFUELBED MEDIA THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS UNLESS THEY HAVE BEEN ADEQUATELY SUPERVISED BY A RESPONSIBLE PERSON TO ENSURE THAT THEY CAN USE THE APPLIANCE SAFELY The data plate for this appliance containing technical information and specifications c...

Page 3: ...e X FIRE 1200 on Setting the Control Mode Locking the Remote Control Contents 1 2 5 Operation from the touch pad 5 Cleaning and Maintenance 8 Normal operating Sounds and Smells 10 Warranty Information 11 Clearances 6 X FIRE 1200 ...

Page 4: ...t the OFF screen it is possible that the remote is locked in the OFF screen to unlock it just press the button below Unlock and then OK Switching on the X FIRE 1200 Switching on Once the remote is unlocked press On left button and OK middle button A beep from the control unit will be heard and the ignition process starts the pilot will start sparking and gas will start flowing to the pilot which s...

Page 5: ...is turned on three options are available AUTO MANUALand MENU Auto and Manual are two of the three different modes for controlling the appliance with the remote If Manual is pressed Pilot appears as the selected setting In the bottom row and appear indicating that the flame level can by changed by just pressing the left or middle button There are four possible flame positions Pilot flame Low flame ...

Page 6: ...de is not enabled To enable program mode enter configuration mode by pressing and holding the OFF button for 40 seconds selecting Programming and selecting yes For more information on configuration mode see the installation manual section 19 9 There are two types of program mode a Daily mode and a Weekly mode In the daily mode every day uses the same program In the weekly mode every day has its ow...

Page 7: ... and the appliance will heat until this temperature is reached To adjust the night temperature press Menu Adjust menu Night and set the desired temperature Large bar The comfort temperature is set as the desired temperature and the appliance will heat until this temperature is reached High bar To adjust the comfort temperature pres Menu Adjust menu Comfort and set the desired temperature Finally t...

Page 8: ... for locking the remote To unlock pres left button and then middle button To turn on the XFIRE 1200 push the ON OFF button on the touch pad The system will emit a beep and begin the ignition process which can take about 20 seconds Once the start up process is complete the pilot flame is lit The XFIRE 1200 is now in the Manual mode and ready to be used While the pilot is lit press the Flame Up or F...

Page 9: ...should not be installed on near or above a heat source For this reason TV location decisions rest solely with the householder and the manufacturer distributor will not be held liable for any adverse affects on a TV located near to the X FIRE 1200 fireplace that may be caused by heat The drawings below are suggestions that may be used as a GUIDE for those consumers who do decide to locate their TV ...

Page 10: ...y to satisfy themselves that their TV mounting and mantle design will not exceed the listed maximum operating temperature of their electronic goods 7 If the entire installation mantle wall and cavity is constructed from materials then the clearances to mantles or protruding surfaces mounted above an may be as shown by the shaded area in the diagram below NON COMBUSTIBLE X FIRE 1200 X FIRE 1200 X F...

Page 11: ... with the matching receptacles on the fire and push the fascia into place and let it drop down the fascia should now be securely in position The X FIRE 1200 fascia attaches to the fire by four hooks To remove the fascia simply lift it upwards 15 20mm and pull towards you Care should always be taken when handling the fascia Ensure the fascia is allowed to cool before handling Annual Servicing Your ...

Page 12: ...he appliance if the glass has been broken damaged or the glass is not properly positioned hooked onto the appliance Cleaning your X FIRE 1200 The unit must be cold before starting any form of maintenance or cleaning The glass can be cleaned using standard window cleaner If you wish the clean the inside of the glass you can remove the glass assembly by following the instructions on page 8 Take care...

Page 13: ... OFF a dull clicking sound may be audible this is normal operation of a valve When the fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burner burns away These are normal and should be no cause for concern Unit Body Firebox Different types and thickness of steel will expand and contract at different rates resulting in some dull ...

Page 14: ...od on parts and labour shall be for twelve 12 months from the date of purchase b Stone facias are made from natural materials which will include natural features such as vents pinholes minor fissures and fossils or other markings These are not regarded as faults and may not be claimed as such under warranty a Acquisitions at its sole discretion will provide replacement parts to the Distributor ret...

Page 15: ...cquisitions reserves the right to discontinue products or make substitutions in such event the buyer may receive a substitute product or a cash refund at Acquisition s sole discretion if a replacement for the product covered by this Limited Warranty is no longer available 6 Acquisitions is not responsible for damage arising from failure to follow instructions for the product s installation mainten...