27
Y1-03-0222 Rev. C
8.
AIS alarm messages (NMEA 0183 ALR, Text)
Local alarm condition and status. This sentence is used to report an alarm condition on a device and its current
state of acknowledgement.
ALR message format
!-- ALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF>
field 1 2 3 4 5
Field
Format
Description
1
x
hhmmss.ss = Time of alarm (UTC)
2
Unique alarm number
3
Alarm condition
4
Alarm acknowledge state
5
Alarm description, text
Alarm descriptions presented are:
AIS: TX malfunction
AIS: Antenna VSWR exceeds limit
AIS: Rx channel 1 malfunction
AIS: Rx channel 2 malfunction
AIS: general failure
AIS: no sensor position in use
AIS: no valid SOG information
AIS: no valid COG information
AIS: 12V alarm
AIS: 5V alarm
AIS: Loss of serial interface integrity
AIS: Background noise above -77dBm
9.
ACK messages
An Acknowledge Message (ACK) can be generated by a minimum keypad and display (MKD) unit, chart plotter
or other display device connected to the N
auticast™-B to acknowledge an alarm condition reported by the
N
auticast™-B.
ACK message format
!-- ACK,xxx*hh <CR><LF>
field 1
Field
Format
Description
1
x
unique alarm number
Summary of Contents for AIS-B - REV C