APPENDIX E - SUPPORT, WARRANTY, USEFUL LIFE and NOTICES  

1. 

Support 

Contact your 

local dealer for Nauticast™-B AIS support. 

Please visit the ACR Website for Service centers near you.  
 

ACR Electronics Europe GmbH 

Handelskai 388 / Top 632 
A-1020 Vienna, Austria 
Tel:  

+43 (1) 5 237 237 - 0 

Fax:  

+43 (1) 5 237 237 - 150 

Email:  

technical.support@acr-europe.com

 

Web:  

www.acr-europe.com

 

ACR Electronics Inc

Technical Service 
5757 Ravenswood Road 
Fort Lauderdale, FL 33312, U.S.A. 
Tel.:  

+1 (954) 981-3333 

Fax: 

+1 (954) 983-5087 

Email: 

service@acrelectronics.com

 

Web: 

www.acrelectronics.com

2. 

Limited Warranty

Limied Warranty 

This product is warranted against factory defects in material and workmanship for a period of 1 (one) year* from 
date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, 
replace the unit

 

at no cost to you for labor, materials and return transportation from ACR. For further assistance, 

please  contact  our  Technical  Service  Department  at  ACR  Electronics,  Inc.,  5757  Ravenswood  Road,  Fort 
Lauderdale,  FL  33312-6645.  Email: 

service@acrelectronics.com

,  Fax:  +1  (954)  983-5087,  Telephone:  +1  (954) 

981- 3333. 
 
This warranty does not apply if the product has been damaged by accident or misuse, or as a result of service or 
modification  performed  by  an  unauthorized  factory.  Except  as  otherwise  expressly  stated  in  the  previous 
paragraph,  THE  COMPANY  MAKES  NO  REPRESENTATION  OR  WARRANTY  OF  ANY  KIND,  EXPRESS  OR 
IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER 
WITH RESPECT TO THIS PRODUCT. The Company shall not be liable for consequential or special damages. 
 
To  place  the  warranty  in  effect,  register  online  at 

www.acrelectronics.com

  or  return  the  attached  card  within  10 

days. 
 
*Five years for the following products: EPIRB, PLB, S-VDR, SSAS 
 

3. 

Useful Life Policy 

The typical service life of a properly maintained Product is limited to 12 years from date of manufacture. Products 
that  are  12  years  and  1  month  or  older  from  date  of  manufacture  will  not  be  serviced  by  ACR  or  our  Battery 
Replacement Centers. A Product that is 12 or less years old from date of manufacture will be serviced as long as 
the  unit  appears  fit  to  be  placed  back  into  its  final  operational  cycle.  Service  includes  the  replacement  of  those 
items  that  must  be  replaced  at  service  intervals  and  the  verification  that  the  device  appears  to  be  in  good 
mechanical and electrical working condition by an ACR authorized service technician. 

 

4. 

Other notices 

 

ACR Electronics diligently works to provide a high quality Product Support Manual, however, despite best efforts, 
information is subject to change without notice, and omissions and inaccuracies are possible. ACR cannot accept 
liability  for  manual  contents.  To  ensure  that  you  have  the  most  recent  version  of  the  Product  Support  Manual, 
please visit the ACR website at 

www.acrelectronics.com

.  

 

In accordance with a policy of continual development and product improvem

ent the Nauticast™-B hardware and 

software  may  be  upgraded  from  time  to  time  and  future  versions  of  the  Nauticast™-B  may  therefore  not 
correspond exactly with this manual. When necessary, upgrades to the product will be accompanied by updates or 
addendums to this manual. 
 
©2008  by  ACR  Electronics,  Inc.,  part  of  Cobham  plc.  All  rights  reserved.  Reproduction  in  whole  or  in  part  is 
permitted  only  with  permission  of  ACR  Electronics,  Inc.  Ongoing  product  improvements  may  change  product 
specifications without notice. 
 
Trademarks or registered trademarks are the property of their respective owners. 

 

 

 

Summary of Contents for AIS-B - REV C

Page 1: ......

Page 2: ...ort scenarios may exist whereby the vessel equipped with this AIS transponder is not visible to other AIS transponders CAUTION Before proceeding to install test or use your new ACR Electronics product...

Page 3: ...______________________________________________22 APPENDIX A SERIAL DATA INTERFACE _________________________________________________22 APPENDIX B SPECIFICATIONS AND WARNINGS ___________________________...

Page 4: ...t ship to ship operation The International Maritime Organization IMO defines the performance standards as follows Ship to ship working ship to shore working including long range application automatic...

Page 5: ...t is heading The scenario below shows a full AIS coverage area including all applications and complete shore infrastructure 2 AIS classes There are two classes of AIS units fitted to vessels Class A a...

Page 6: ...rammed the transponder will need to be returned to ACR for factory reset Information transmitted from vessels that have a Class A AIS transponders on board include Name of Vessel Destination Size of V...

Page 7: ...umber Please contact the relevant authority in your country for more information The application will install and launch automatically A Start Menu folder and shortcut will be created with the name Li...

Page 8: ...n Installation of the Link2AIS Software Program later in this section 4 Installation of the NET Framework You may install the NET framework from the original CD or you can download it from the Microso...

Page 9: ...rosoft website terminate the download process by clicking the Cancel button in the download dialog box and install the package directly from the CD Locate the file dotnetfx exe and double click it to...

Page 10: ...r in order to install the Link2AIS Software 6 Installation of the Link2AIS Software Unzip the downloaded package when necessary Locate the files setup exe and the accompanying msi file then double cli...

Page 11: ...Rev C A dialog box will appear reminding you to uninstall any prior versions of the Link2AIS software if applicable before continuing the install process Read through and accept the license agreement...

Page 12: ...you to pick options to be installed These options are checked by default Choose a directory where the software will be installed Make note of this directory as you will need to manually copy files to...

Page 13: ...0222 Rev C The software will ask you to choose a location in the Start menu to place the program s shortcuts The next screen will ask you to confirm the install settings you have provided in the previ...

Page 14: ...on has been completed Click Finish Finally find the Coastlines folder on the installation CD and copy to the install directory chosen during the install process If you are unable to find this director...

Page 15: ...nd supply the Nauticast B AIS with 12V of power ACR recommends that you connect the AIS to your boat s power and connect it to a laptop in order to easily program your AIS before physically mounting t...

Page 16: ...at the bottom left of the application window 8 Help file There is a context based Help file which explains what each data entry field means and what sort of data is expected 9 Software structure The...

Page 17: ...nearest meter o Dimension B distance from the GPS antenna location to the stern to the nearest meter o Dimension C distance from the port side to the GPS antenna location to the nearest meter o Dimens...

Page 18: ...ix section of this manual for details of the power data and RF cables supplied Using the two co axial leads supplied connect the down lead from a VHF antenna to the VHF antenna port and connect the do...

Page 19: ...unit is 0 5m or greater for 0 3 deviation 12 Antenna installation Antenna connections on the transponder GPS antenna This is a TNC female bulkhead connector that mounts to the side of the transponder...

Page 20: ...shared with any other VHF transmitter receiver Should be mounted with at least a two meter vertical separation distance from any other VHF antenna used for speech or DCS communication Also see Appendi...

Page 21: ...nel 88B 162 025MHz to regularly transmit information such as the vessel position Maritime Mobile Service Identity MMSI name speed course etc Receives similar information from other AIS equipped vessel...

Page 22: ...illuminated it is not possible to send another SRM An SRM can be sent once a minute The payload within the message 14 transmission is the text string MAYDAY MAYDAY Silent Mode Function if user configu...

Page 23: ...nt information source ACS messages Alarm messages ALR TXT The data interface will accept Personality programming messages Alarm acknowledgement messages ACK 3 Power up messages On power up the unit wi...

Page 24: ...clause 5 3 2 of the AIS unit for an ACA sentence NOTE 4 This field supports a maximum of 62 valid characters for messages transferred using multiple sentences and 63 valid characters for messages usin...

Page 25: ...ge identification number It is used to identify the sentences containing portions of the same message This allows for the possibility that other sentences might be interleaved with the message sentenc...

Page 26: ...n and Channel Management functions of the AIS unit as described in ITU R M 1371 ACA message format ACA x llll ll a yyyyy yy a llll ll a yyyyy yy a x xxxx x xxxx x x x a x hhmmss ss field 1 2 3 4 5 6 7...

Page 27: ...d are AIS TX malfunction AIS Antenna VSWR exceeds limit AIS Rx channel 1 malfunction AIS Rx channel 2 malfunction AIS general failure AIS no sensor position in use AIS no valid SOG information AIS no...

Page 28: ...200 b s 30 ppm FSK RX Sensitivity Sensitivity 107dBm 25kHz Message Error Rate 20 Co Channel 10dB Adjacent Channel 70dB IMD 65dB Blocking 84dB Environmental IEC 60945 Operating Temperature 25 C to 55 C...

Page 29: ...position reports or causing damage to the transponder and activating the red LED WARNING regarding radio frequency exposure To meet the requirements for Radio Frequency Exposure it is necessary to in...

Page 30: ...B 10 Tinned Copper BLACK 22 24 CABLE 2 RS422 RX B 11 Tinned Copper WHITE 22 24 CABLE 2 SW1GND 15 Tinned Copper BLACK 22 24 CABLE 3 SW1 Switch 8 Tinned Copper PURPLE 22 24 CABLE 3 RS232 TX 12 2 Tinned...

Page 31: ...nline at www acrelectronics com or return the attached card within 10 days Five years for the following products EPIRB PLB S VDR SSAS 3 Useful Life Policy The typical service life of a properly mainta...

Page 32: ...nkel 10 D 32825 Blomberg Germany Certificate No 07 110244 Regulations and IMO MSC 74 69 Annex 3 Standards ITU R M 1371 1 Class B IALA Technical Clarification of ITU R M 1371 1 Ed 1 4 ITU R M 825 3 ITU...

Reviews:

Related manuals for AIS-B - REV C