Y1-03-0212-1 Rev D
59
Case A:
1h x ( 0.5 I TX + I RX + I Add ) x 1.4 = 44.06 Ah
recommend battery capacity is 86 Ah
Charger:
I Charg x 0.1 I Batt/h = 8.6 A
recommend charger is type 20 A
Case B:
6h x ( 0.5 I TX + I RX + I Add ) x 1.4 = 264.39 Ah
The battery calculation should not be used for uninterruptible power supply (UPS)
configuration