12/11/2021 912S-03765-01.00
13
USER MANUAL
3.1
Functional test
To test your ResQLink AIS is functioning correctly, press and hold the TEST/OFF Key. The LED will
illuminate red
to indicate the key has been pressed, then start flashing. Release the TEST Key
now. After a short pause the strobe
will flash and the indicator LED will produce a flash
sequence.
The flash sequence indicates the total number of hours that the battery has already been in use, up to
the time that the test was initiated.
3.1.1
LED Indications with RLS Enabled
No. of Flashes
Functional Test Pass
Fail
1
0 to 59min
1hr to 1hr 59min
121.5MHz homer
2
2hrs to 3hrs 59min
406MHz power
3
4hrs to 5hrs 59min
AIS signal
4
6hrs to 7hrs 59min
AIS Power
5
8hrs to 9hrs 59min
Battery failure
6
10hrs +
No GNSS
3.1.2
LED Indications for units configured with non-RLS Protocol
No. of Flashes
Functional Test Pass
Fail
1
0 to 59min
1hr to 1hr 59min
121.5MHz homer
2
2hrs to 3hrs 59min
406MHz power
3
4hrs to 5hrs 59min
AIS signal
4
6hrs to 7hrs 59min
AIS Power
5
8hrs to 9hrs 59min
Battery failure
6
10hrs +
No GNSS
!
Because this test transmits a short burst on the aircraft distress frequency of 121.5MHz,
please only carry out this test in the first 5 minutes of each hour.
!
The battery must be replaced either prior to the expiry date shown on the rear label or
after the ResQLink AIS has been activated.
!
If, during a self test, the LED flashes magenta
or amber
the ResQLink AIS may
not have sufficient energy to operate for the specified 24-hour period. Battery replace-
ment is recommended.
NOTE:
The flash sequence will be repeated after a short pause and then the ResQLink AIS
will automatically power off.
NOTE:
A single AIS transmission will occur during a Functional Test indicating “MOB
TEST” on AIS receivers within range.