The diagrams above assume that
the life jacket inflation tube is on the left hand side of the jacket
(as viewed from the front).
If the oral tube is on the right hand side then the ResQLink AIS should be fitted on the other side of
the tube.
5.1
Remove the Activation Slider
!
The ResQLink AIS will turn on during this process, make sure it is turned off by pressing
and holding the TEST/OFF Key until the LED flashes red twice and release.
!
Take great care to keep well clear of eyes and face
as the antenna will be released very quickly. Keep
at least 30cm (12”) clear to avoid possible injury.
•
Slide the red arming tab down.
•
Slide the grey slide sideways off the unit.
!
Turn off the ResQLink AIS by pressing the
TEST/OFF Key until the LED flashes red twice and
release.
5.2
Securing the Activation System
1.
To prevent accidental loss, use the provided length of cord to tether the Antenna Rewind
tool, Activation Slider and Protective cover. Attaching these parts will prevent them falling
into the water upon activation and ensure they are available for re-use.
2.
Tie a knot in one end of the cord and pass the other end through the Rewind tool, Activation
Cover and Activation Slider tying another knot as shown below.