USER MANUAL
22
912S-03765-01.00 12/11/2022
6.
BEACON CONFIGURATION
6.1
Pre-configured Beacons
ResQLink AISs are supplied to the user already configured. The configuration details will be clearly
marked on the product labels and the packaging. In all cases the user must register the ResQLink
AIS with the relevant National Authority using the information supplied on these labels.
Configuration Details
Beacon unique Identification Number
Country for which the beacon is programmed
Cospas Sarsat TAC Number
RLS On (Enabled) / Off (Disabled)
AIS self identification number
Unit Serial Number
Battery Expiry Date
7.
APPENDIX
7.1
Maintenance and Troubleshooting
Your ResQLink AIS will require little maintenance except periodic cleaning, if required. Always use a
damp cloth to clean the case and dry thoroughly.
!
Do not use solvents or other cleaning fluids as this may cause the plastics to deteriorate.
!
Ensure the antenna is free to unwind.
!
Should the ResQLink AIS turn on during cleaning, make sure it is turned off as quickly as
possible by pressing and holding the TEST/OFF Key until the LED flashes red twice and
release.
7.2
Batteries
The ResQLink AIS contains Lithium iron batteries for long operating life. The battery must be replaced
either prior to the expiry date shown on the rear label or after the ResQLink AIS has been used, even
if only activated for a short period of time. The battery condition can be determined by carrying out
the Self Test procedure shown in section 3 of this manual.
!
Battery replacement must be carried out at an ACR Electronics authorised battery
replacement centre using manufacturer supplied battery components.
!
DO NOT ATTEMPT TO REPLACE THE BATTERIES YOURSELF
The ResQLink AIS is a life saving device and unauthorised opening and battery replace-
ment may cause the unit to fail upon activation putting your life a risk.
!
Store between -30°C (-22ºF) to+70°C (+158ºF)
!
Do not short circuit, incinerate or recharge.