ACEX4041 COM Express Type 10
AcroPack Carrier Board
- 41 -
FIELD GROUNDING CONSIDERATIONS
The Field I/O signals are isolated from chassis and system ground on the
carrier. However, some non-isolated AcroPack modules connect Field I/O
ground to system ground. Care should be taken in designing installations
without isolation to avoid ground loops and noise pickup. This is particularly
important for analog I/O applications when a high level of accuracy/resolution
is needed (12-bits or more). Contact your Acromag representative for
information on our many isolated signal conditioning products that could be
used to interface to the AcroPack input/output modules.
3.
PROGRAMMING INFORMATION
This ACEX4041 carrier board has no end user programmable components. The
PCIe switch on the carrier is transparent to the end user.