SERIES AP440 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 15 - http://www.acromag.com
- 15 -
www.acromag.com
ground loops.
2.6 Logic Interface Connector
The AP module logic edge connector interfaces to the mating connector on
the carrier board. The pin assignments of this connector are standard for all
AP modules according to the PCI Express MINI Card Electromechanical
Specification, REV 1.2 (with exceptions shown in Table 2.2 and noted
below).
Threaded metric M2.5 screws and spacers are supplied with the AP module
carriers and conduction cooling kit to provide additional stability for harsh
environments.
Power su5, +12, and -12 Volt have been assigned to pins that are
reserved in the mini-PCIe specification. The Present signal is grounded on
the AP module. In addition, COEX1, COEX2 – wireless transmitter control
are reassigned to JTAG signals TMS and TCK. Lastly, UIM_C4, UIM_C8 –
reserved User Identity Module signals are reassigned to JTAG signals TDI and
TDO.
Table 2.2: Logic Interface
Connections
Pin #
Name
Pin #
Name
51
+5V
2
52
+3.3V
3
49
+12V
2
50
GND
47
-12V
2
48
+1.5V
45
Present
2
46
N.C. (LED_WPAN#)
1
43
GND
44
N.C. (LED_WLAN#)
1
41
+3.3V
3
42
N.C. (LED_WWAN#)
1
39
+3.3V
3
40
GND
37
GND
38
N.C. (USB_D+)
1
35
GND
36
N.C. (USB_D-)
1
33
PETp0
34
GND