SERIES AP440 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 49 - http://www.acromag.com
- 49 -
www.acromag.com
Figure 2 AP440 and AP445 Loopback Interconnect
LOAD
LOAD
LOAD
LOAD
COM
COM
COM
COM
COM
COM
COM
COM
OD
OD
OD
OD
IN
IN
IN
IN
-V
-V
+V
+V
AP440 INPUT
AP440 INPUT
AP440 INPUT
AP440 INPUT
AP445 OUTPUT
AP445 OUTPUT
AP445 OUTPUT
AP445 OUTPUT
AP445 OUTPUT TO AP440 INPUT LOOPBACK CONNECTIONS
AP445 CONNECTED
AS A HOT-SIDE
SWITCH
AP445 CONNECTED
AS A LOW-SIDE
SWITCH
AP445 CONNECTED
AS A LOW-SIDE
SWITCH
AP445 CONNECTED
AS A HIGH (HOT)
-SIDE SWITCH
NOTE THAT FOR LOOPBACK PURPOSES, THE COMMON LINE OF AN AP440 PORT AND THE
COMMON LINE OF AN AP445 PORT DO NOT NECESSARILY CONNECT TOGETHER.
THE AP440 & AP445 INCLUDE 4 PORTS OF 8 CHANNELS EACH. EACH PORT SHARES A PORT
COMMON. SEPARATE PORT COMMONS FACILITATE PORT TO PORT ISOLATION. THE AP445 ALSO
INCLUDES SEPARATE PORT SUPPLY PINS FOR CONNECTING TO THE ON-BOARD PULLUPS.
COM
ODXX
COM
SUPPLY
INXX
5V
470
AP440 INPUT
INPUT: 4-18V
AP445 OUTPUT
When interfacing digital output levels to the AP440, use the model AP440-1E-LF (4V threshold) and adjust the
external pullup value accordingly. The AP445E-LF should pullup should be 470 ohm. Field I/O pinouts of the
AP440 and AP445 are directly compatible. The AP445E-LF includes a pullup supply pin for each port at pin 5