Table 3.8: FPGA Voltage and
Temperature Range
Minimum
Typical
Maximum
Vccint
0.95
1.0
1.05
Vccaux
1.71
1.8
1.89
Temperature
operating range
-40C
50-60C
100C
Firmware Revision Register (Read Only) - (BAR0 + 0x0000 0200)
This is a read only register. The ASCII code representing the current revision
of the MCS firmware file is readable from this location. For example, if the
firmware is at revision A then this register will read 0x41 in the least
significant byte or B= 0x42, C=0x43, etc.