6.0 SPECIFICATIONS
6.1 Physical
Height:
12.5 mm (0.4921 in)
Height defines Carrier to Module Maximum component height
Board Thickness
1.0 mm (0.03937 in)
AcroPack L x W: 70 mm x 30.00 mm
(2.76 in x 1.18 in)
Unit Weight (does not include shipping material):
AcroPack 0.2624 oz (7.5 g)
6.2 Power Requirements
6.3 Environmental Considerations
6.3.1 Operating Temperature
Model Number
Description
Temp Range
AP470E-LF
48-Channel Digital I/O
-40
o
C to 85
o
C
1
Note 1: Applications requiring operating temperatures of 70°C to
85°C will require purchase of AcroPack Heatsink Accessory AP-CC-
01 with a minimum airflow of 200LFM. For temperature below
70°C the module will require a minimum airflow of 200LFM.
AP-CC-01 AcroPack Conduction Cool Kit (See Appendix B for
installation instructions)
Summarized below are the expected current draws for each of the specified power supply voltages.
Power Supply Voltage
Current Draw
3.3 VDC +/- 5%
1
400 mA Typical
600 mA Max
1.5 VDC +/- 5%
1
Not Used
5.0 VDC +/- 5%
1
0.5 mA (All Outputs OFF)
60 mA (All Outputs ON w/ 4.7 kΩ pull-ups)
+12 VDC +/- 5%
Not Used
-12 VDC +/- 5%
1
Not Used
Summarized below are the operating temperature range, airflow
and other environmental requirements and applicable standards for
the AcroPack module.