SERIES AP470 ACROPACK  

USER

’S MANUAL 

 

 

 

Acromag, Inc. Tel: 248-295-0310  

            - 50 -                                   

http://www.acromag.com  

- 50 - 

www.acromag.com 

 

 

4.

 

AP-CC-01 Installation is complete. 

 

 

 

 

 

Note: 

Make sure the thermal pad is 

making contact with the FPGA IC. 

Summary of Contents for AcroPack AP470 Series

Page 1: ...O Module USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Fax 248 624 9234 Copyright 2016 Acromag Inc Printed in the USA Data and specifications are...

Page 2: ...rmation 6 1 3 2 Key Features 6 1 3 3 Key Features PCIe Interface 7 1 4 Signal Interface Products 7 1 5 Software Support 8 Windows 8 VxWorks 8 Linux 8 1 6 References 8 2 0 PREPARATION FOR USE 9 2 1 Unp...

Page 3: ...s 0 5 28 Event Polarity Control Register For Ports 0 3 Enhanced Mode Bank 1 Port 6 Write Only 28 Table 3 14 Event Polarity Control Register For Ports 0 3 Port 6 28 Event Polarity Control Register For...

Page 4: ...4 1 Logic Power Interface 42 4 2 I O Ports 42 5 0 SERVICE AND REPAIR 43 5 1 Service and Repair Assistance 43 5 2 Preliminary Service Procedure 43 5 3 Where to Get Help 43 6 0 SPECIFICATIONS 44 6 1 Ph...

Page 5: ...S MANUAL Acromag Inc Tel 248 295 0310 4 http www acromag com 4 www acromag com APPENDIX A 47 AP470 Functional Block Diagram 47 APPENDIX B 48 AP CC 01 Heatsink Kit Installation 48 CERTIFICATE OF VOLATI...

Page 6: ...ep current the information contained in this manual No part of this manual may be copied or reproduced in any form without the prior written consent of Acromag 1 2 1 Trademark Trade Name and Copyright...

Page 7: ...nd programmable debounce Interrupt event and debounce functionality applies to all 48 channels of this model The AP470 utilizes state of the art Surface Mounted Technology SMT to achieve its wide func...

Page 8: ...ower up or power down for steady and safe control Open Drain Outputs Include Pull ups All outputs include 4 7K pull ups to 5V Overvoltage Protection Individual I O channels include over voltage clamps...

Page 9: ...Acromag provides a software product sold separately consisting of VxWorks software This software Model APSW API VXW is composed of VxWorks real time operating system libraries for all AcroPack module...

Page 10: ...oduct near strong electrostatic electromagnetic magnetic or radioactive fields unless the device is contained within its original manufacturer s packaging Be aware that failure to comply with these gu...

Page 11: ...ovided to prevent a temperature rise above the maximum operating temperature 2 3 Non Isolation Considerations The board is non isolated since there is electrical continuity between the PCIe bus and Ac...

Page 12: ...9 Field I O 6 12 Reserved isolation 11 Reserved isolation 4 4 7 14 Field I O 7 38 29 8 13 Field I O 8 16 Reserved isolation 15 Reserved isolation 5 5 9 18 Field I O 9 39 30 10 17 Field I O 10 20 Rese...

Page 13: ...ed isolation 55 Reserved isolation 15 15 29 58 Field I O 29 49 40 30 57 Field I O 30 60 Reserved isolation 59 Reserved isolation 16 16 31 62 Field I O 31 50 41 32 61 Field I O 32 64 Reserved isolation...

Page 14: ...I O 43 56 47 44 85 Field I O 44 88 Reserved isolation 87 Reserved isolation 23 23 45 90 Field I O 45 57 48 46 89 Field I O 46 92 Reserved isolation 91 Reserved isolation 24 24 47 94 Field I O 47 58 4...

Page 15: ...e mating connector on the carrier board The pin assignments of this connector are standard for all AP modules according to the PCI Express MINI Card Electromechanical Specification REV 1 2 with except...

Page 16: ...23 PERn0 24 3 3V3 21 GND 22 PERST 19 TDI UIM_C4 1 20 N C W_DISABLE 1 17 TDO UIM_C8 1 18 GND 15 GND 16 N C UIM_VPP 1 13 RECLK 14 N C UIM_RESET 1 11 REFCLK 12 N C UIM_CLK 1 9 GND 10 N C UIM_DATA 1 7 CLK...

Page 17: ...ration registers A PCIe bus configuration access is used to access an AcroPack s configuration registers When the computer is first powered up the computer s system configuration software scans the PC...

Page 18: ...ve on a board interrupt request Table 3 1 Configuration Registers Reg Num D31 D24 D23 D16 D15 D8 D7 D0 0 Device ID 0x7016 AP470 Vendor ID 16D5 1 Status Command 2 Class Code 118000 Rev ID 00 3 BIST Hea...

Page 19: ...d Port 7 which is the Mask Register If the Enhanced Mode is selected then 3 additional banks of 8 registers are addressed to cover the additional functionality in this mode The first bank of the Enhan...

Page 20: ...0000 0000 7 0 Interrupt Register 0x0000 0004 7 0 Location in System Register Table 3 2 Standard Mode Memory Map Notes 1 The AP470 will respond to addresses that are Not Used The board will return 0 fo...

Page 21: ...x0000 000C 7 0 READ WRITE Port 1 I O Register IO08 IO15 0x0000 0010 7 0 READ WRITE Port 2 I O Register IO16 IO23 0x0000 0014 7 0 READ WRITE Port 3 I O Register IO24 IO31 0x0000 0018 7 0 READ WRITE Por...

Page 22: ...lear Reg Port 1 I O points 8 15 0x0000 0010 7 0 READ Port 2 Event Sense Status Reg Port 2 I O points 16 23 0x0000 0010 7 0 WRITE Port 2 Event Sense Clear Reg Port 2 I O points 16 23 0x0000 0014 7 0 RE...

Page 23: ...nd to addresses that are Not Used The board will return 0 for all address reads that are not used or reserved BAR0 Base Address Bit s Description 0x0000 0008 7 0 READ WRITE Port 0 Debounce Control Reg...

Page 24: ...3 7 This register can be read or written with either 8 bit 16 bit or 32 bit data transfers A power up or system reset sets all interrupt register bits to 0 With both an enabled Event Sense bit and Boa...

Page 25: ...arrier XXXXX System Slot identification bits are described by the AcroPack carrier card 31 to 8 Not Used Port Registers Standard Mode Ports 0 5 Read Write BAR0 0x0000 0008 0x0000 001C Six registers ar...

Page 26: ...of operation To switch to Enhanced Mode four unique bytes must be written to port 7 in consecutive order without doing any reads or writes to any other port and with interrupts disabled The data patte...

Page 27: ...ort 3 Write Mask Port 3 Write Mask 4 Port 4 Write Mask Port 4 Write Mask 5 Port 5 Write Mask Port 5 Write Mask 6 Bank Select Bit 0 Bank Status Bit 0 7 Bank Select Bit 1 Bank Status Bit 1 Bits 6 7 of t...

Page 28: ...terrupt Enable bits are set then interrupts can be generated Changing Debounce control registers while interrupts are enabled can cause false interrupts It is recommended that interrupts be disabled p...

Page 29: ...0020 A write to this register controls the polarity of the input sense event for nibbles of ports 0 3 channels 0 31 four channels at a time A 1 written to a bit in this register will cause the corres...

Page 30: ...ed until enabled via the Event Sense Status Clear Register Further interrupts will not be reported to the system unless the Interrupt enable bit 0 has been configured for enable via the Interrupt Regi...

Page 31: ...ter Read Bit s FUNCTION 5 to 0 NOT USED 7 to 6 00 Bank 0 Read Inputs 01 Bank 1 Event Status Clear 10 Bank 2 Event Debounce Control Reset Duration 11 INVALID DO NOT WRITE Debounce Control Register Enha...

Page 32: ...ounce for ports 0 3 If the debounce clock selected is the 31 25MHz internal system clock see Debounce Clock Select Register then the debounce times are selected as shown below actual times vary to wit...

Page 33: ...egister controls the duration required by each input signal before it is recognized by each individual input in the Enhanced Mode both inputs and event inputs Register 1 controls debounce for ports 4...

Page 34: ...0 5 of this register are not used Bits 6 7 of this register are used to select the bank of registers to be addressed In Enhanced Mode three banks banks 0 1 2 of eight registers may be addressed Bank...

Page 35: ...ers The 10 bits digitized and output from the ADC can be converted to temperature by using the following equation 15 273 1024 975 503 ADCcode C e Temperatur The 10 bits digitized and output from the A...

Page 36: ...0 1 05 Vccaux 1 71 1 8 1 89 Temperature operating range 40C 50 60C 100C Firmware Revision Register Read Only BAR0 0x0000 0200 This is a read only register The ASCII code representing the current revi...

Page 37: ...al ports may also be masked from writes to the port when the port is intended for input only to help prevent contention errors Each port I O line includes an integrated 4 7k pull up resistor to 5V For...

Page 38: ...ve or low to high level transitions positive Set each half port nibble to the desired polarity and then enable each of the event inputs to be detected Optionally set the interrupt enable bit the Inter...

Page 39: ...hannels Interrupts are only generated in the Enhanced Mode for event channels when enabled via the Event Sense Status Register Writing 0 to the corresponding event sense bit in the Event Sense Status...

Page 40: ...point you are in Enhanced Mode bank 0 Port 7 is used to access register banks 1 2 2 Write 80H to the port 7 address to select register bank 2 where debounce will be configured for our port 0 input ch...

Page 41: ...tatus Register for port 0 I O points at the port 0 address in this bank Note that writing a 1 to a bit position enables the event sense detector while writing a 0 clears the event sensed without enabl...

Page 42: ...vent Sense Status Register must be written with a 1 to re enable event sensing for subsequent events but only after first writing 0 to the corresponding bit position to clear the event sense flip flop...

Page 43: ...tion to each other As such care must be taken to avoid ground loops Ignoring this effect may cause operation errors and with extreme abuse possible circuit damage A Field Programmable Gate Array FPGA...

Page 44: ...OFF BEFORE SERVICING BOARDS Before beginning repair be sure that all of the procedures in the Preparation for Use section have been followed Also refer to the documentation of your carrier board to v...

Page 45: ...ations requiring operating temperatures of 70 C to 85 C will require purchase of AcroPack Heatsink Accessory AP CC 01 with a minimum airflow of 200LFM For temperature below 70 C the module will requir...

Page 46: ...with IEC 60068 2 27 30G 11ms half sine 50G 3mS half sine 18 shocks at 6 orientations for both test levels 6 3 5 EMC Directives The AcroPack is designed to comply with EMC Directive 2004 108 EC Immuni...

Page 47: ...t Capacitance 20pF Max 10pF Typical Input Leakage Current 10 A Typical 6 6 Digital Outputs Output Channel Configuration 48 open drain CMOS outputs For DC voltage applications only observe proper polar...

Page 48: ...SERIES AP470 ACROPACK USER S MANUAL Acromag Inc Tel 248 295 0310 47 http www acromag com 47 www acromag com Appendix A AP470 Functional Block Diagram Figure 1 AP470 Block Diagram...

Page 49: ...Tel 248 295 0310 48 http www acromag com 48 www acromag com Appendix B AP CC 01 Heatsink Kit Installation This example will show how to install the AP CC 01 Heatsink kit with an APCe7020 carrier AP CC...

Page 50: ...K USER S MANUAL Acromag Inc Tel 248 295 0310 49 http www acromag com 49 www acromag com 1 Install two standoffs and secure with two screws 2 Install the AcroPack module 3 Install the Heatsink and secu...

Page 51: ...S AP470 ACROPACK USER S MANUAL Acromag Inc Tel 248 295 0310 50 http www acromag com 50 www acromag com 4 AP CC 01 Installation is complete Note Make sure the thermal pad is making contact with the FPG...

Page 52: ...Sanitize Power Down Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is reta...

Page 53: ...ry The revision history for this document is summarized in the table below Release Date Version EGR DOC Description of Revision 30 MAR 2016 A MDW MDW Preliminary Document Publication 18 JUL 2016 A MDW...

Reviews: