SERIES AP220 / AP231 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 17 -
http://www.acromag.com
- 17 -
https://www.acromag.com
0x0000 0018
31:0
DAC Channel 4
0x0000 001C
31:0
DAC Channel 5
0x0000 0020
31:0
DAC Channel 6
0x0000 0024
31:0
DAC Channel 7
0x0000 0028
31:0
DAC Channel 8
0x0000 002C
31:0
DAC Channel 9
0x0000 0030
31:0
DAC Channel 10
0x0000 0034
31:0
DAC Channel 11
0x0000 0038
31:0
DAC Channel 12
0x0000 003C
31:0
DAC Channel 13
0x0000 0040
31:0
DAC Channel 14
0x0000 0044
31:0
DAC Channel 15
0
x
0000 0048
31:0
Simultaneous Mode
0x0000 004C
31:0
Simultaneous Output Trigger
0x0000 0050
31:0
Not Used
0x0000 0054
31:0
DAC Write Status
0x0000 0058
31:0
DAC Reset Control
0x0000 005C
→0x00
000084
31:0
Not Used
0x0000 0088
XADC Status/Control Register
0x0000 008C
XADC Address Register
0x0000 0090
→0x00
0001FC
Not Used
0x0000 0200
31:0
Firmware Revision
0x0000 0204
7:0
Flash Data
0x0000 0208
Bit-0
Flash Chip Select
0x0000 020C
→0x00
0007FF
31:0
Not Used
Module Location In System Register (Read Only) - (BAR0 + 0x0000 0004)
This read only register is used
identify the module’s plugin location in a
system.