SERIES AP220 / AP231 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 33 -
http://www.acromag.com
- 33 -
https://www.acromag.com
6.2 Power Requirements
6.3 Environmental Considerations
6.3.1 Operating Temperature
Model Number
Description
Temp Range
AP220E-LF
16 Channels of 12-bit Analog
Output
-40°
C
to 85°
C
1
AP231E-LF
16 Channels of 16-bit Analog
Output
-40°
C
to 85°
C
1
Note 1
: Applications requiring operating temperatures of 70°C to 85°C will
require purchase of AcroPack Heatsink Accessory AP-CC-01 and minimum
airflow of 400LFM. For temperatures below 70°C the module will require a
minimum airflow of 200LFM
AP-CC-01 AcroPack Conduction Cool Kit
(See Appendix for
installation instructions)
Summarized below are the expected current draws for each of the specified
power supply voltages.
(The current draw is the same for both AP220E and AP231E)
Power Supply Voltage Current Draw
•
+3.3 VDC +/- 5%
1
400 mA Typical, 480 mA maximum
•
+12 VDC +/- 5%
1
85 mA Typical, 275 mA maximum
•
-12 VDC +/- 5%
1
50 mA Typical, 200 mA maximum
Note 1
:
Typical current draw is using an AP220E with APCe7020E-LF
Summarized below are the operating temperature range, airflow
and other environmental requirements and applicable standards for
the AcroPack module.