SERIES AP220 / AP231 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 34 -
http://www.acromag.com
- 34 -
https://www.acromag.com
6.3.2 Other Environmental Requirements
6.3.2.1 Relative Humidity
The range of acceptable relative humidity is 5% to 95% non-condensing.
6.3.2.2 Isolation
The PCIe bus and field commons are non-isolated and have a direct electrical
connection.
6.3.3 Vibration and Shock Standards
The AcroPack is designed to pass the following Vibration and Shock
standards.
Vibration, Operating:
MIL-STD-810G, Method 514.6
Procedure I (General Vibration)
Category 20 (Ground vehicles/ground mobile)
8-500Hz, Sinusoidal 5Grms X, Y and Z axis. 1hr per axis (15 minute sweep up
/ 15 minute sweep down test duration)
Shock, Operating:
MIL-STD-810G, Method 516.6
Procedure I (functional Shock)
50g, 11ms half-sine 3 positive/negative per axis (Total of 18 drops)
6.3.4 EMC Directives
The AcroPack is designed to comply with EMC Directive 2004/108/EC.
•
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-3.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
Surge Immunity, per IEC 61000-4-5.
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
•
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16.
Low Voltage AC Mains Port, per CISPR 16.
Note:
This is a Class A product