INDUSTRIAL I/O PACK SERIES APC8620/8621                                                          PCI BUS CARRIER BOARD
___________________________________________________________________________________________

- 4 -

This board is physically protected with
packing material and electrically protected
with an anti static bag during shipment.   It
is recommended that the board be visually
inspected for evidence of mishandling prior
to applying power.

The board utilizes static sensitive
components and should only be handled at
a static-safe workstation.

CARD CAGE CONSIDERATIONS

Refer to the specifications for loading and power

requirements.   Be sure that the system power supplies are able
to accommodate the power requirements of the carrier board,
plus the installed IP modules, within the voltage tolerances
specified.

IMPORTANT: Adequate air circulation must be provided to
prevent a temperature rise above the maximum operating
temperature.

The lack of air circulation within the computer chassis is a

cause for some concern.  Most, if not all, computer chassis do
not provide a fan for cooling of add-in boards.  The dense
packing of the IP modules to the carrier board alone results in
elevated IP module and carrier board temperatures, and the
restricted air flow within the chassis aggravates this problem.
Adequate air circulation must be provided to prevent a
temperature rise above the maximum operating temperature and
to prolong the life of the electronics.  If the installation is in an
industrial environment and the board is exposed to environmental
air, careful consideration should be given to air-filtering.

BOARD CONFIGURATION

The carrier board is plug-and-play compatible and, as such,

its board addresses are automatically assigned by the system
auto-configuration routine upon power-up.  The base address of
the carrier board’s configuration registers in memory space and
I/O space is assigned.  In addition, the base address of the IP
modules and carrier board registers are assigned in 32-bit
memory space.

Power should be removed from the board when installing IP

modules, cables, termination panels, and field wiring.  Refer to
Mechanical Assembly Drawing 4501-672 and your IP module
documentation for specific configuration and assembly
instructions.

Interrupt Configuration

No hardware jumper configuration is required.  All interrupt

enabling, and status are configured via programmable registers
on the carrier board (see Section 3 for programming details).  The
carrier board passes interrupt requests from the IP modules to
the PCI bus.  Refer to the IP modules for their specific
configuration requirements.

CONNECTORS

Connectors of the APC8620 carrier consist of five (three for

APC8621) carrier IP module field I/O connectors, five (three for

APC8621) IP module logic connectors, and one PCI bus interface
connector.  These interface connectors are discussed in the
following sections.

Carrier Field I/O Connectors (IP modules A through E)

Field I/O connections are made via 50 pin ribbon cable

connectors A, B, C, D, and E (A, B, and C for APC8621) for IP
modules in positions A through E (A through C for APC8621).  IP
module assignment is marked on the board for easy identification
(see IP location drawing 4501-671 or 4501-676 for physical
locations of the IP modules).  Flat cable assemblies and
Acromag termination panels (or user defined terminations) can be
quickly mated to the field I/O connectors.  Pin assignments are
defined by the IP module employed since the pins from the IP
module field side correspond identically to the pin numbers of the
50 pin connectors.

Carrier field I/O connectors A through E (A through C for

APC8621) are industry standard 50-pin low profile headers (male)
with short ejector latches (no ejector latches for APC8621) and
they mate to ribbon cable connectors (3M Type P/N 3425-6600).

IP Field I/O Connectors (IP modules A through E)

The field side connectors of IP modules A through E (A

through C for APC8621) mate to AMP 173280-3 connectors P4,
P5, P9, P12, and P15 (P3, P6, and P9 for APC8621)
respectively, on the carrier board.  IP location is silk-screened on
the board for easy identification.  Field and logic side connectors
are keyed to avoid incorrect assembly.

The AMP 173280-3 connectors mate to AMP 173279-3

connectors (or similar) on the IP modules.  This provides
excellent connection integrity and utilizes gold plating in the
mating area.  Threaded metric M2 screws and spacers (supplied
with Acromag IP modules) provide additional stability for harsh
environments (see Drawing 4501-672 for assembly details).

Pin assignments for these connectors are made by the

specific IP model used and correspond identically to the pin
numbers of the front panel connectors.

IP Logic Interface Connectors (IP modules A through E)

The logic interface sides of IP modules A through E (A

through C for APC8621) mate to AMP 173280-3 connectors P6,
P7, P10, P13, and P16 (P4, P7, and P10 for APC8621),
respectively, on the carrier board.  IP location is silk-screened on
the board for easy identification.  Field and logic side connectors
are keyed to avoid incorrect assembly.

The AMP 173280-3 connectors mate to AMP 173279-3

connectors (or similar) on the IP modules.  This provides
excellent connection integrity and utilizes gold plating in the
mating area.  Threaded metric M2 screws and spacers (supplied
with Acromag IP modules) provide additional stability for harsh
environments (see Drawing 4501-672 for assembly details).

Pin assignments for these connectors are defined by the IP

module specification and are shown in Table 2.1.

IP Logic Strobe Connectors

Each IP module has an uncommitted Strobe signal on the

logic interface connector (pin 46).  The Strobe signal may be
used as an optional input or output from the IP module.  On the
APC8620 the Strobe signals for each of the five IP modules are
routed on the printed circuit board to the location just above the

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for APC8620 Series

Page 1: ...cess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respect...

Page 2: ...D 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8500 576 E01B010 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...501 671 APC8620 IP LOCATIONS 13 4501 676 APC8621 IP LOCATIONS 14 4501 672 MECHANICAL ASSEMBLY DRAWING 15 4501 673 APC8620 8621 BLOCK DIAGRAM 16 4501 462 CABLE 5025 550 NON SHIELDED 17 4501 463 CABLE 5025 551 SHIELDED 18 4501 464 TERMINATION PANEL 5025 552 19 IMPORTANT SAFETY CONSIDERATIONS It is very important for the user to consider the possible adverse effects of power wiring component sensor o...

Page 4: ...the read cycle is retried This allows the PCI bus to be free for other system operations while the read data is moved to the read FIFO Interrupt Support PCI bus INTA interrupt request is supported All IP module interrupts are mapped to INTA Carrier board software programmable registers are utilized as interrupt request control and status monitors SIGNAL INTERFACE PRODUCTS See Appendix for more inf...

Page 5: ...ield I O Connectors IP modules A through E Field I O connections are made via 50 pin ribbon cable connectors A B C D and E A B and C for APC8621 for IP modules in positions A through E A through C for APC8621 IP module assignment is marked on the board for easy identification see IP location drawing 4501 671 or 4501 676 for physical locations of the IP modules Flat cable assemblies and Acromag ter...

Page 6: ...Signal 12V B01 A01 TRST TCK B02 A02 12V Ground B03 A03 TMS TDO B04 A04 TDI 5V B05 A05 5V 5V B06 A06 INTA INTB B07 A07 INTC INTD B08 A08 5V PRSNT1 B09 A09 Reserved Reserved B10 A10 5V PRSNT2 B11 A11 Reserved Signal Pin Pin Signal Ground B12 A12 Ground Ground B13 A13 Ground Reserved B14 A14 Reserved Ground B15 A15 RST CLK B16 A16 5V Ground B17 A17 GNT REQ B18 A18 Ground 5V B19 A19 Reserved AD 31 B20...

Page 7: ...on registers A PCI bus configuration access is used to access a PCI card s configuration registers PCI Configuration Address Space When the computer is first powered up the computer s system configuration software scans the PCI bus to determine what PCI devices are present The software also determines the configuration requirements of the PCI card The system software accesses the configuration reg...

Page 8: ... in Tables 3 3 Table 3 3 APC8620 8621 Carrier Bd Memory Map Base Address Hex High Byte D15 D08 Low Byte D07 D00 Base Address Hex 0001 Bit 8 Software Reset Carrier Board Status Control 0000 0003 IP Interrupt Pending Register 0002 0005 IP A Interrupt 0 Select Space 0004 0007 IP A Interrupt 1 Select Space 0006 0009 IP B Interrupt 0 Select Space 0008 000B IP B Interrupt 1 Select Space 000A 000D IP C I...

Page 9: ...ror Refer to your IP specific documentation to see if the error signal is supported and what it indicates Reset condition Set to 0 IP Interrupt Pending Register Read Base 02H The IP Interrupt Pending Register is used to individually identify pending IP interrupts or a pending carrier generated interrupt as a result of IP module time out access If multiple IP interrupts are pending software must de...

Page 10: ...e IP module is designed to release it s interrupt request on register access the interrupt service routine must access the required register to clear the interrupt request 14 Write End Of Interrupt command to PC AT s 8259 15 If the IP interrupt stimulus has been removed and no other IP modules have interrupts pending the interrupt cycle is completed i e the carrier board negates its interrupt requ...

Page 11: ...ee section 3 for programming details The interrupt service routine should respond to an interrupt by accessing IP Interrupt Select INTSEL space The interrupt service routine should also conclude the interrupt routine by writing the End Of Interrupt command to the PC AT s 8259 interrupt controller see section 3 for more details Power Failure Monitor The carrier board contains a 5 volts undervoltage...

Page 12: ... measured from falling edge of FRAME to the falling edge of TRDY PCI bus Read Cycle Time 150nS Typical The carrier issues a RETRY which frees the PCI bus while the read request is completed The PCI bus will repeat the same read request until it completes with the requested data Write Complete Time Time from FRAME active until LRDYi active 650nS Typical carrier register 750nS Typical 8 bit and 16 b...

Page 13: ... and Physical Attributes For Non Shielded cable model see Drawing 4501 462 For Shielded cable model see Drawing 4501 463 Shipping Weight 1 0 pound 0 5Kg packed CABLE MODEL 5029 943 Type Model 5029 943 IP500 Communication Cable A five foot long flat 50 pin cable with a female connector on one end for connection to carrier board and four DE 9P connectors serial ports on the other end Application Use...

Page 14: ... APC8620 IP LOCATIONS C F7 F11 F9 F8 IPC F10 F12 D E F13 F15 IPD B A 4 200 3 362 IPA F2 F1 F3 F6 F5 IPB F4 2 508 0 608 0 190 0 591 1 605 0 295 F14 3 525 IPE 0 200 0 150 0 325 4501 671B FUSES 5V 2 AMP 12V 1 AMP 12V 1 AMP F3 5 8 11 14 F2 4 7 12 15 F1 6 9 10 13 12 283 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 15: ...__________________________________ 14 APC8621 IP LOCATIONS F4 F8 F5 F1 F3 F9 IPC F2 F6 F7 C FUSES F1 2 3 F4 6 8 F5 7 9 5V 2 AMP 12V 1 AMP 12V 1 AMP 0 325 0 608 3 362 4 200 A B IPA IPB 2 508 1 605 0 591 0 295 0 190 6 600 4501 676A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 16: ...C8620 CARRIER BOARD SHOWN 2 INSERT FLAT HEAD SCREWS ITEM A THROUGH SOLDER SIDE OF IP MODULE AND INTO HEX SPACERS ITEM B AND TIGHTEN 4 PLACES UNTIL HEX SPACER IS COMPLETELY SEATED M2 x 6 FLAT HEAD SCREW THREADED M2 3 CAREFULLY ALIGN IP MODULE TO CARRIER BOARD AND PRESS TOGETHER UNTIL CONNECTORS AND SPACERS ARE SEATED 4 INSERT PAN HEAD SCREWS ITEM C THROUGH SOLDER SIDE OF CARRIER BOARD AND INTO HEX ...

Page 17: ...PC8620 8621 PCI BUS CARRIER BOARD ___________________________________________________________________________________________ 16 4501 673B Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 18: ...PC8620 8621 PCI BUS CARRIER BOARD ___________________________________________________________________________________________ 17 4501 462A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 19: ...PC8620 8621 PCI BUS CARRIER BOARD ___________________________________________________________________________________________ 18 4501 463A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 20: ...PC8620 8621 PCI BUS CARRIER BOARD ___________________________________________________________________________________________ 19 4501 464A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 21: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: