Add the current for the AcroPack module to calculate the total current
required from each supply.
The carrier is designed to provide the following voltage and currents to the
AcroPack module.
Supply Voltage
Current (Max)
+12V +/- 8% (max)
0.5 A
-12V +/- 8% (max)
0.5 A
+5V +/- 5% (max)
0.5 A
+3.3V +/- 5% (max)
1.1 A
+1.5V +/- 5% (max)
0.5 A
+3.3Vaux +/- 9% (max)
100m A
The carrier board pr1.5V, +3.3V, +5V, +12V and -12V power to the
AcroPack module. The APCe7012E-LF utilizes DC/DC converters to generate
the +1.5V, +5V and -12V supplies from the +3.3V and +12V. Each AcroPack
module supply line is individually fused. Note that the maximum amount of
current provided to the carrier card via the PCIe bus edge connector varies
with each system. Refer to your system documentation for more information
on PCIe power specifications.
Fuses
+1.5 1.1 Amps (F6) Raychem NANOSMDC110F-2
+3.3V 3 Amps (F4) Littelfuse 0466003.NR
+5V, +12V, -12V 2 Amps (F1, F2, F3) Littelfuse 0453002.MR
PCIe BUS COMPLIANCE
Specification This device meets or exceeds all written PCI Express
specifications per revision 2.1.
ENVIRONMENTAL
Operating Temperature -40 to +85
°
C (with 200 LFM airflow)
Relative Humidity 5-95% non-condensing
Storage Temperature -55 to +125
°
C.
EMC Compliance
The APCe7012E-LF is designed to comply with EMC Directive 2004/108/EC.
Immunity per EN 61000-6-2
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2
Radiated Field Immunity (RFI), per IEC 61000-4-3
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4
Surge Immunity, per IEC 61000-4-5
Conducted RF Immunity (CRFI), per IEC 61000-4-6
Emissions per EN61000-6-4
Enclosure Port, per CISPR 16
Low Voltage AC Mains Port, per CISPR 16
Note: This is a Class A product