Ser
ies
AVME9125 VMEbus
6U A
nalog Input Boar
d
___________________________________________________________________________________________
- 20 -
ANALOG COMMON
2. REFERENCE CHANNELS TO ANALOG COMMON, IF THEY WOULD OTHERWISE BE FLOATING. CHANNELS ALREADY
HAVING A GROUND REFERENCE MUST NOT BE CONNECTED TO ANALOG COMMON, TO AVOID GROUND LOOPS.
1. SHIELDED CABLE IS RECOMMENDED FOR LOWEST NOISE. SHIELD IS CONNECTED TO GROUND REFERENCE
AT ONE END ONLY TO PROVIDE SHIELDING WITHOUT GROUND LOOPS.
NOTES:
CH16-31
EXT. SOURCE 16-31
SEE NOTE 2
SEE NOTE 1
SHIELD
-DCH15
+DCH16-31
-DCH16-31
CH00
CH01
CH15
EXT. SOURCE 15
EXT. SOURCE 1
EXT. SOURCE 0
ANALOG INPUT CONNECTION DIAGRAM
+DCH00
-DCH00
+DCH01
-DCH01
+DCH15
+
-
AVME9125
ANALOG
COMMON
EARTH GROUND
CONNECTION AT
POWER SUPPLY
(TYPICAL)
DIGITAL
COMMON
4501-688A