SERIES IP1K110 INDUSTRIAL I/O PACK RECONFIGURABLE DIGITAL I/O MODULE
__________________________________________________________________________________________
- 18 -
Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:solutions@acromag.com
http://www.acromag.com
IP1K110 Engineering Design Kit
Model IP-1K110-EDK.............. Engineering design kit provides
the user with the basic
information required to develop a
custom FPGA program for
download to the Altera FPGA.
The design kit includes a CD
containing: schematics, parts list,
part location drawing, example
VHDL source, example
configuration file, and other utility
files. The IP1K110 is intended
for users fluent in the use of
Altera MaxPlus II or Quartus II
design tools.
NineK468d.hex
1
........................
Hexadecimal (Intel-Format)
configuration file. The Hex file is
an ASCII file in the Intel Hex
format. The file is generated by
the Altera software and is used to
program the Altera FPGA over
the IP bus interface.
NineK468d.vhd
1
........................
.
Acromag provided VHDL
(hardware design language)
source file supports IP bus
interface to ID, IO, and INT
space.
clkgene.vhd
1
.........................
Acromag provided VHDL
(hardware design language)
source file that provides a
interface for programming the
CY22150.
NineK468d.acf
1
.........................
.
Altera Maxplus II ASCII text file
that stores information about
connected pin, and device
assignments, as well as
configuration settings for the
Compiler, Simulator, and Timing
Analyzer for an entire project.
File can be imported to Quartus II
Clock Generator
Clock Generator IC................... Cypress CY22150
Frequency range 250KHz to
100MHz.
BitCalc2k1.exe......................... C executable program which
provides the register values need
to program the clock generator
chip for your selected frequency.
This program is included in the
Engineering Design kit for the
IP1K110.
1. The final letter of the file name indicates revision number and
may differ from the files provided.
APPENDIX
CABLE: MODEL 5025-551-x (Shielded)
Type: Flat Ribbon Cable, 50-wires (female connectors at both
ends). The ‘-x’ suffix designates the length in feet (12 feet
maximum). Choose shielded cable according to model
number. The shielded cable is highly recommended for
optimum performance with analog input or output modules.
Application: Used to connect a Model 5025-552 termination
panel to the AVME9630/9660, APC8610, or APC8620/1 non-
intelligent carrier board connectors (both have 50-pin
connectors).
Length: Last field of part number designates length in feet (user-
specified, 12 feet maximum). It is recommended that this
length be kept to a minimum to reduce noise and power loss.
Cable: 50-wire flat ribbon cable, 28 gage. Shielded cable model
uses Acromag Part 2002-261 (3M Type 3476/50 or
equivalent).
Headers (Both Ends): 50-pin female header with strain relief.
Header -
Acromag Part 1004-512 (3M Type 3425-6600 or
equivalent).
Strain Relief -
Acromag Part 1004-534 (3M Type
3448-3050 or equivalent).
Keying: Headers at both ends have polarizing key to prevent
improper installation.
Schematic and Physical Attributes: See Drawing 4501-463.
Shipping Weight: 1.0 pound (0.5Kg) packaged.
TERMINATION PANEL: MODEL 5025-552
Type: Termination Panel For AVME9630/9660, APC8610, or
APC8620 Boards
Application: To connect field I/O signals to the Industrial I/O
Pack (IP).
Termination Panel:
Acromag Part 4001-040
(Phoenix Contact Type FLKM 50). The 5025-552 termination
panel facilitates the connection of up to 50 field I/O signals
and connects to the AVME9630/9660 3U/6U, APC8610, or
APC8620/1 non-intelligent carrier boards (field connectors
only) via a flat ribbon cable (Model 5025-551-x). The A-D
connectors on the carrier board connect the field I/O signals
to the P2 connector on each of the Industrial I/O Pack
modules. Field signals are accessed via screw terminal
strips. The terminal strip markings on the termination panel
(1-50) correspond to P2 (pins 1-50) on the Industrial I/O Pack
(IP). Each Industrial I/O Pack (IP) has its own unique P2 pin
assignments. Refer to the IP module manual for correct
wiring connections to the termination panel.
Schematic and Physical Attributes: See Drawing 4501-464.
Field Wiring: 50-position terminal blocks with screw clamps.
Wire range 12 to 26 AWG.
Connections to AVME9630/9660, APC8610, or APC8620/1: P1,
50-pin male header with strain relief ejectors. Use Acromag
5025-551-x cable to connect panel to VME board. Keep
cable as short as possible to reduce noise and power loss.
Mounting: Termination panel is snapped on the DIN mounting
rail.
Printed Circuit Board: Military grade FR-4 epoxy glass circuit
board, 0.063 inches thick.
Operating Temperature: 0 to +70
°
C.
Storage Temperature: -25
°
C to +85
°
C.
Shipping Weight
: 1.25 pounds (0.6kg) packaged.