IP482 Industrial I/O Pack User’s Manual Counter Timer Module
___________________________________________________________________
________________________________________________________________________________________
Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:solutions@acromag.com http://www.acromag.com
27
Bit(s)
FUNCTION
2,1,0
Specifies the Counter Mode:
100
Event Counting
3
Output Polarity (Output Pin ACTIVE Level):
0
Active LOW (Default)
1
1
Active HIGH
5, 4
InA Polarity / Gate-Off
00
Disabled (Default)
01
Active LOW
In A=0: Continue Counting
In A=1: Stop Counting
10
Active HIGH
In A=0: Stop Counting
In A=1: Continue Counting
11
Disabled
7, 6
InB Polarity / Event Input
00
Disabled (Default)
01
Active LOW Events
10
Active HIGH Events
11
Disabled
9,8
InC Polarity / External Trigger
00
Disabled (Default)
01
Active LOW Trigger
10
Active HIGH Trigger
11
Up when logic low /Down when logic high
Count Control
12,11,10
Specifies the Counter Mode:
000
Event Counting
13
Input Debounce Enable
0
Disabled (Default)
– No Debounce Applied to any
Input.
1
Enabled
– Reject Gate-Off, Event Input, Up/Down or
Trigger Pulses (noise) less than or equal to 2.5
s.
14
Not Used (bit reads back as 0)
15
Interrupt Enable
0
Disable Interrupt Service (Default)
1
Enable Interrupt Service
COUNTER CONTROL
REGISTER
EVENT COUNTING
OPERATION
Table 3.13:
Counter Control
Register
(Event Counting)
1. The default state of the
output pin is high (output has
pullup installed). Bit 3
specifies the active output
polarity when the output is
driven.