Bit(s)
FUNCTION
2,1,0
Specifies the Counter Mode:
100
Frequency Measurement
3
Output Polarity (Output Pin ACTIVE Level):
0
Active LOW (Default)
1
1
Active HIGH
5, 4
InA Polarity / Enable Pulse of Known Width
00
Disabled (Default)
01
Active LOW Pulse
10
Active HIGH Pulse
11
Disabled
7, 6
InB Polarity / Signal Measured/Counted
00
Disabled (Default)
01
Active LOW Pulse Counted
10
Active HIGH Pulse Counted
11
Disabled
9,8
InC Polarity / External Trigger
00
Disabled (Default)
01
Active LOW Trigger
10
Active HIGH Trigger
11
Disabled
12,11,10
Specifies the Counter Mode:
111
Frequency Measurement
13
Input Debounce Enable
0
Disabled (Default)
– No Debounce Applied to any
Input.
1
Enabled
– Reject Frequency Input Enable, or Trigger
Pulse (noise) less than or equal to 2.5
s.
14
Not Used (bit reads back as 0)
15
Interrupt Enable
0
Disable Interrupt Service (Default)
1
Enable Interrupt Service
COUNTER CONTROL
REGISTER
FREQUENCY
MEASUREMENT
OPERATION
Table 3.14:
Counter Control
Register
(Frequency Measurement)
1. The default state of the
output pin is high (output has
pullup resistor installed). Bit 3
specifies the active output
polarity when the output is
driven.