background image

SERIES IP503 INDUSTRIAL I/O PACK                  EIA/TIA-232E & CENTRONICS COMMUNICATION MODULE
___________________________________________________________________________________________

- 3 -

• 

Interrupt Support - Individually controlled transmit, receive,
line status, and data set interrupts may be generated.
Unique interrupt vectors may be assigned to each port.
Interrupt generation uses a priority shifting scheme based on
the last interrupt serviced, preventing the continuous
interrupts of one port from freezing out the interrupts of
another port

• 

Internal Diagnostic Capabilities - Loopback controls for
communication link fault isolation.  Break, parity, overrun,
and framing error simulation is also possible

• 

Industry Standard 16550 Family UART w/16C450 Mode -
The UART of this device is a member of the industry
standard 16C550 family of UART’s and remains software
compatible.  Additionally, this device can operate in a
16C450 UART family software compatible mode.  The
transmit and receive channels are double-buffered in this
mode.  Hold and shift registers eliminate the need for
precise synchronization between the host CPU and the
serial data

INDUSTRIAL I/O PACK INTERFACE FEATURES

• 

High density - Single-size, industry standard, IP module
footprint.  Four units mounted on a carrier board provide up
to 8 serial ports and 4 parallel ports in a single system slot.
Both VMEbus and ISAbus (PC/AT) carriers are supported

• 

Local ID - Each IP module has its own 8-bit ID PROM which
is accessed via data transfers in the "ID Read" space

• 

8-bit I/O - Port register Read/Write is performed through 8-
bit data transfer cycles in the IP module I/O space

• 

High Speed - Access times for all data transfer cycles are
described in terms of "wait" states--2 wait states are
required for all read and write operations.  One wait state is
required for an ID PROM read.  See Specifications section
for detailed information

SIGNAL INTERFACE PRODUCTS
(See Appendix for more information on compatible products)

This IP module will mate directly to any industry standard IP

carrier board (including Acromag AVME9630/9660 3U/6U non-
intelligent VMEbus carrier boards)Additionally, PC carrier boards
are also supported (see Acromag Model APC8600)A wide range
of other Acromag IP modules are also available to serve your
signal conditioning and interface needs

Note: Since all connections to field signals are made through the
carrier board which passes them to the individual IP modules,
you should consult the documentation of your carrier board to
ensure compatibility with the following interface products

Cables:

Model 5025-551-X (Shielded Cable), or Model 5025-550-X
(Non-Shielded Cable):A Flat 50-pin cable with female
connectors at both ends for connecting AVME9630/9660, or
other compatible carrier boards, to Model 5025-552
termination panels.  The unshielded cable is recommended
for digital I/O, while the shielded cable is recommended for
optimum performance with precision analog I/O applications.
The “-X” suffix of the model number denotes the length in feet

Model 5029-944 IP503 Serial Communication Cable:  A 5
foot long, flat 50-pin cable with a female connector on one
end (for connection to AVME9630/9660 or other compatible
carrier boards) and two DE-9P connectors (serial ports), plus
one DB-25S connector (parallel port) on the other end

Model 5029-900 APC8600 High-Density Cable:  A 36-inch
long interface cable that mates the high-density (25mil pitch)
50-pin I/O connectors of the APC8600 PCbus carrier board,
to the high-density connectors on the APC8600 Termination
Panel (described below)

Termination Panels:

Model 5025-552: A DIN-rail mountable panel that provides 50
screw terminals for universal field I/O termination.  Connects
to Acromag AVME9630/9660, or other compatible carrier
boards, via flat 50-pin ribbon cable (Model 5025-550-X or
5025-551-X)

Model 5029-910 APC8600 High-Density-to-Screw-Terminal
Termination Panel:  This panel converts the high-density
ribbon-cable connectors coming from the APC8600 carrier
board (Acromag cable Model 5029-900) to screw terminals,
for direct-wired interfaces

Transition Module:

Model TRANS-GP:  This module repeats field I/O
connections of IP modules A through D for rear exit from a
VMEbus card cage.  It is available for use in card cages
which provide rear exit for I/O connections via transition
modules (transition modules can only be used in card cages
specifically designed for them)It is a double-height (6U),
single-slot module with front panel hardware adhering to the
VMEbus mechanical dimensions, except for shorter printed
circuit board depth.  It connects to Acromag Termination
Panel 5025-552 from the rear of the card cage, and to
AVME9630/9660 boards within the card cage, via flat 50-pin
ribbon cable (cable Model 5025-550 or 5025-551)

INDUSTRIAL I/O PACK SOFTWARE LIBRARY

Acromag provides an Industrial I/O Pack Software Library

diskette (Model IPSW-LIB-M03, MSDOS format) to simplify
communication with the board.  Example software functions are
provided for both ISAbus (PC/AT) and VMEbus applications.  All
functions are written in the “C” programming language and can be
linked to your application.  For more details, refer to the
“READMETXT” file in the root directory on the diskette and the
“INFO503TXT” file in the appropriate “IP503” subdirectory off of
“\VMEIP” or “\PCIP”, according to your carrier

20 PREPARATION FOR USE

UNPACKING AND INSPECTION

Upon receipt of this product, inspect the shipping carton for

evidence of mishandling during transit.  If the shipping carton is
badly damaged or water stained, request that the carrier's agent
be present when the carton is opened.  If the carrier's agent is
absent when the carton is opened and the contents of the carton
are damaged, keep the carton and packing material for the
agent's inspection

For repairs to a product damaged in shipment, refer to the

Acromag Service Policy to obtain return instructions It is
suggested that salvageable shipping cartons and packing
material be saved for future use in the event the product must be
shipped

Summary of Contents for Series IP503

Page 1: ...tion Module USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1995 Acromag Inc Printed in the USA Data and spe...

Page 2: ...toring system This is especially important where economic property loss or human life is involved It is important that the user employ satisfactory overall system design It is agreed between the Buyer...

Page 3: ...m performance with precision analog I O applications The X suffix of the model number denotes the length in feet Model 5029 944 IP503 Serial Communication Cable A 5 foot long flat 50 pin cable with a...

Page 4: ...n assignments are unique to each IP model see Table 21 and normally correspond to the pin numbers of the field I O interface connector on the carrier board you should verify this for your carrier boar...

Page 5: ...ground to safety ground via any device connected to these ports or a ground loop will be produced and this may adversely affect operation The communication cabling of the P2 interface carries digital...

Page 6: ...ing Little Endian uses even byte addresses to store the low order byte As such use of this module on an ISAbus PC AT carrier board will require the use of the even address locations to access the 8 bi...

Page 7: ...transmitted then data is right justified to the LSB If parity is used then LCR bit 3 parity enable and LCR bit 4 type of parity are required Status for the receiver is provided via the Line Status Reg...

Page 8: ...gh to low transition start bit When the start bit is detected a counter is reset and counts the 16x sampling clock to 7 1 2 which is the center of the start bit The receiver then counts from 0 to 15 t...

Page 9: ...NOT supported by this model FIFO Control Register FCR BIT FUNCTION 0 When set to 1 this bit enables both the Tx and Rx FIFO s All bytes in both FIFO s can be cleared by resetting this bit to 0Data is...

Page 10: ...m Control Register 1 MCR Bit 4 provides a local loopback feature for diagnostic testing of the UART channel When set high the UART serial output connected to the TXD driver is set to the marking logic...

Page 11: ...d by a read of the IIR Line Status Register continued LSR Bit FUNCTION PROGRAMMING 6 Transmitter Empty TEMT 0 Not Empty 1 Transmitter Empty set when both the Transmitter Holding Register THR and the T...

Page 12: ...data lines This register is either output only or bi directional depending on the state of the extended mode bit bit 0 of the LEM register and the data direction control bit bit 5 of the LPC register...

Page 13: ...interrupt source the ACKN line of the parallel port or bit 2 of the LPS register The serial ports and the parallel port interrupts drive INTREQ0 Bit 0 of this register drives the ENIRQ line of the UA...

Page 14: ...atus of each channel can be read by the host CPU at any time during operation Two registers are used to report the status of a serial channel the Line Status Register LSR and the Modem Status Register...

Page 15: ...s the last stop bit time when the following occurs Bit 5 of the LSR THRE is 1 and there is not a minimum of two bytes at the same time in the transmit FIFO since the last time THRE 1The first transmit...

Page 16: ...Divisor Latch Access bit to permit access to the two divisor latch bytes used to set the baud rate These bytes share addresses with the Receive and Transmit buffers and the Interrupt Enable Register...

Page 17: ...puters are considered DTE devices while modems are DCE devices The EIA TIA 232E interface is the fifth revision of this standard and defines an unbalanced single ended transmission standard for unidir...

Page 18: ...ver a null modem cable connection is required to connect two like configured DTE ports due to the imbalance of drivers and receivers see Drawing 4501 572 Pins 1 18 of field I O connector P2 provide co...

Page 19: ...S INPUT BUSY Pin 11 Input Line Printer Busy Active high signal from the printer that is asserted when the printer is not ready to accept more Data The state of this bit is monitored via Bit 7 of the L...

Page 20: ...o obtain parts and repair PRELIMINARY SERVICE PROCEDURE Before beginning repair be sure that all of the procedures in Section 2 Preparation For Use have been followed Also refer to the documentation o...

Page 21: ...t maximum Choose shielded or unshielded cable according to model number The unshielded cable is recommended for digital I O while the shielded cable is recommended for optimum performance with precisi...

Page 22: ...Boards Application This panel converts the high density ribbon cable connectors coming from the APC8600 carrier board Acromag cable Model 5029 900 to screw terminals for direct wired interfaces This p...

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Reviews: