VPX4812/4814
User’s Manual
Single-Slot 3U VPX Bus XMC Carrier Card/Switch Card Module
Acromag, Inc. Tel: 248-295-0310 - 22 - www.acromag.com
Environmental
Caution
The VPX4812 requires air-flow of at least 200 linear-feet/minute for the
air cooled version
, plus what is required
for an XMC device installed on this module. If the
conduction cooled
version is operating on an extender card, it
requires air-flow of at least 300 linear-feet/minute across it. Versions using the
REDI covers
must not be operated
outside of a fully configured and fully installed conduction cooled REDI system.
Thermal
* w/ 200 lfm airflow
1
must operate in a fully installed conduction-cooled rack
2
must operate in a fully installed conduction-cooled REDI rack
Relative Humidity
5% to 95% non-condensing
Vibration and Shock Standards
Vibration, Random Operating:
Designed to comply with VITA 47 Class V1. Shall
withstand vibration from 5 to 100Hz. with Power Spectral Density (PSD) = 0.04g2/Hz, for
1 hour per axis. Testing shall be in accordance with MIL-STD-810, Method 514,
Procedure 1
Shock, Operating:
Designed to comply with VITA 47 Class OS1, 20g, 11ms half sine and
terminal sawtooth shock pulses. 3 shock pulses in each direction along 3 axes (36
shocks, total). Testing shall be in accordance with MIL-STD-810, Method 516, Procedure
1.
OPERATING
NON-OPERATING
Air-cooled
Conduction-cooled
REDI Cover, Conduction-cooled
0° to 70°C*
-40° to 85°C*
1
-40° to 85°C*
2
-40° to 85°C
-40° to 105°C
-40° to 105°C