VPX4812/4814 

User’s Manual

 

Single-Slot 3U VPX Bus XMC Carrier Card/Switch Card Module 

Acromag, Inc. Tel: 248-295-0310                                                    - 25 -                                                www.acromag.com 

Appendix A 

 Accessory Modules 

 

TRANS-V112 

 

The TRANS-V112 is the rear transition module for the VPX4812 and is used in 
backplanes that bring out the rear I/O signals from the VPX4812. If you are using a 
custom backplane, you will not need the RTM. 

 

The TRANS-V112 brings out the P16 rear I/O signals from the XMC slot on the VPX4812. 
The signals are brought out by two high speed Samtec differential pair connectors (PN 
QTH-020-01-F-D-DP-A-K).  

 

 

 

 

 

Summary of Contents for VPX4812

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...d with P16 Support VPX Switch Card USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Copyright 2019 Acromag Inc Printed in the USA Data and specifica...

Page 3: ...this manual and makes no commitment to update or keep current the information contained in this manual No part of this manual may be copied or reproduced in any form without the prior written consent...

Page 4: ...onal Block Diagram 10 5 0 Board Layout 11 6 0 Connectors 12 P0 Connector 12 P1 Connector 12 P2 Connector 13 J15 Connector 13 J16 Connector 14 J5 Connector JTAG Header 14 7 0 Switch Settings 15 Front P...

Page 5: ...cromag Inc Tel 248 295 0310 4 www acromag com EMI EMC Regulatory Compliance 23 11 0 Service and Repair 24 Service and Repair Assistance 24 Preliminary Service Procedure 24 Where to Get Help 24 Appendi...

Page 6: ...tion typically to a CPU to communicate with up to three downstream Fat Pipe connections or a single Double Fat Pipe connection The VPX4812 also provides support for a VPX Double Fat Pipe x8 connection...

Page 7: ...eds When utilizing the VPX4812 as a switch card a CPU module configured to be an upstream port can communicate with up to three downstream VPX cards in the system as well as an XMC module on the 4812...

Page 8: ...r range of OpenVPX backplane profiles including profiles that contain Ethernet control plane interfaces on P1 Build Levels The VPX4812 14 is available in three electrically compatible build levels eac...

Page 9: ...8 295 0310 8 www acromag com 2 0 Ordering Information Available Models VPX4812 LF VPX4812 Air cooled Model VPX4812 CC LF VPX4812 Conduction cooled Model VPX4812 REDI LF VPX4812 REDI Model VPX4814 LF V...

Page 10: ...uggested that salvageable shipping cartons and packing material be saved for future use in the event the product must be shipped This board is physically protected with packing material and electrical...

Page 11: ...VPX4812 4814 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Acromag Inc Tel 248 295 0310 10 www acromag com 4 0 Operational Block Diagram...

Page 12: ...VPX4812 4814 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Acromag Inc Tel 248 295 0310 11 www acromag com 5 0 Board Layout...

Page 13: ...RXN GND PCIE_VPX_P4_TXP PCIE_VPX_P4_TXN GND Unused 6 GND PCIE_VPX_P5_RXP PCIE_VPX_P5_RXN GND PCIE_VPX_P5_TXP PCIE_VPX_P5_TXN GND 7 PCIE_VPX_P6_RXP PCIE_VPX_P6_RXN GND PCIE_VPX_P6_TXP PCIE_VPX_P6_TXN G...

Page 14: ...6_DP15_P GND J16_DP14_N J16_DP14_P GND 15 J16_DP17_N J16_DP17_P GND J16_DP16_N J16_DP16_P GND Unused 16 GND J16_DP19_N J16_DP19_P GND J16_DP18_N J16_DP18_P GND J15 Connector A B C D E F 1 PCIE_XMC_P0_...

Page 15: ...J16_SIO10_P J16_DP09_P J16_DP09_N J16_SIO11_P 10 GND GND J16_SIO8_N GND GND J16_SIO9_N 11 J16_DP10_P J16_DP10_N J16_SIO8_P J16_DP11_P J16_DP11_N J16_SIO9_P 12 GND GND J16_SIO6_N GND GND J16_SIO7_N 13...

Page 16: ...Pipe D ON ON ON OFF XMC SW2 FRUSEL ORBGND 1 2 default FRU uses 3 3V 2 3 FRU uses 3 3V_AUX 4 5 default Orb ground is connected to digital ground 5 6 Orb ground is isolated from digital ground Orb grou...

Page 17: ...ard EEPROM device to enable Non Transparent Mode SW4 4 SYSTEM CLOCK SELECT ON Common Uses the 100MHz reference clock pins on the VPX bus generated by the CPU board for PCIe timing Pins E8 F8 on the VP...

Page 18: ...e The fifth LED on the front panel indicates the PCIe link status of an XMC module connected to the VPX4812 The table below describes what the LED On Off patterns indicate about the corresponding port...

Page 19: ...tion of floor surfaces d Operation of ion blowers and ion air guns 3 Designated work areas must be kept free of static generating materials such as Styrofoam vinyl plastic fabrics or any other static...

Page 20: ...s are keyed to prevent cards from being inserted into incorrect backplane slot s to avoid electrical incompatibility The VPX4812 has receptacles for these guide pins see the Connectors section By defa...

Page 21: ...l options Power Requirements The VPX4812 requires 3 3V and 5V from the VPX backplane The 12V supplies are used only if required by the XMC module Power Consumption No XMC Card Installed 3 3V 1W 5V 2 6...

Page 22: ...components being out of reset typically takes 250ms Since the ramp up times of the 3 3 V and 5 V system power source and the onboard power source will vary with load the time taken for the VPX4812 to...

Page 23: ...n a fully installed conduction cooled rack 2 must operate in a fully installed conduction cooled REDI rack Relative Humidity 5 to 95 non condensing Vibration and Shock Standards Vibration Random Opera...

Page 24: ...rective 2004 108 EC Immunity per EN 61000 6 2 Electrostatic Discharge Immunity ESD per IEC 61000 4 2 Radiated Field Immunity RFI per IEC 61000 4 3 Electrical Fast Transient Immunity EFT per IEC 61000...

Page 25: ...refer to the documentation for the XMC module to verify that it is correctly configured Replacement of the module with one that is known to work correctly is a good technique to isolate a faulty modul...

Page 26: ...V112 is the rear transition module for the VPX4812 and is used in backplanes that bring out the rear I O signals from the VPX4812 If you are using a custom backplane you will not need the RTM The TRA...

Page 27: ..._SIO5_N GND Unused Unused GND 13 J16_SIO3_P J16_SIO3_N GND J16_SIO2_P Unused GND Unused 14 GND J16_SIO1_P J16_SIO1_N GND Unused Unused GND 15 J16_DP01_N J16_DP01_P GND J16_DP00_N Unused GND Unused 16...

Page 28: ...6 J16_DPO11_P 7 J16_DPO1_N 8 J16_DPO11_N 9 J16_DPO2_P 10 J16_DPO12_P 11 J16_DPO2_N 12 J16_DPO12_N 13 J16_DPO3_P 14 J16_DPO13_P 15 J16_DPO3_N 16 J16_DPO13_N 17 J16_DPO8_P 18 J16_DPO9_P 19 J16_DPO8_N 2...

Page 29: ...J16_DP04_N 4 J16_DP14_N 5 J16_DP05_P 6 J16_DP15_P 7 J16_DP05_N 8 J16_DP15_N 9 J16_DP06_P 10 J16_DP16_P 11 J16_DP06_N 12 J16_DP16_N 13 J16_DP07_P 14 J16_DP17_P 15 J16_DP07_N 16 J16_DP17_N 17 J16_DP18_P...

Page 30: ...ed when power is removed Yes No Type EEPROM Flash etc EEPROM AT25640B Size 64 KB User Modifiable Yes No Function Store settings for PEX8624 PCIe switch Process to Sanitize Device can be accessed via S...

Page 31: ...n History The following table shows the revision history for this document Release Date Version EGR DOC Description of Revision 4 25 2014 A MDW ARP Initial Acromag release 9 13 2016 B MDW ARP Added VP...

Page 32: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: