Max inrush, A
40
Input current
AC input
Max. current
100–127 Vac, 8.8 A
200–240 Vac, 4.3 A
Power supply efficiency
(Platinum class)
10% load
20% load
50% load
100% load
80%
90%
94%
91%
Input power factor correction
1
Output power
20% load
50% load
100% load
Power factor
>0.80
>0.95
>0.95
1
Tested at 230 Vac, 50 Hz and 115 Vac, 60 Hz. The input power factor is greater than values in the
table at power supply’s rated output and meets Energy Star® requirements.
8.2 Environmental specifications
Acronis Cyber Appliance environmental specifications are listed in the following tables.
Store temperature
-40°C to 85°C (-40°F to 185°F)
Store temperature gradient
20°C (68°F) per hour
Operating temperature
10°C to 35°C (50°F to -95°F)
Operating temperature gradient
20°C (68°F) per hour
Relative humidity percentage range for storage
10% ~ 95% (non-condensing)
Relative humidity percentage range for operating
10% ~ 85% (non-condensing)
Vibration for storage
1.87 Grms (10-500 Hz)
Vibration for operating
0.26 Grms (5-350 Hz)
Shock for storage
65G for 2ms
Shock for operating
5G
Altitude for storage
12,000m (39,370 ft)
Altitude for operating
3,048m (10,000 ft)
8.2.1 Air quality requirements
The air must be free of:
l
Corrosive dust and corrosive contaminants
l
Conductive dust and conductive particles (such as zinc whiskers)
31