ANR-C62xN1 Series
50
Acrosser Technology Co., Ltd.
Command
Code
Command Name
Data Format
Number of
Data Bytes
D3h
READ_3V3_IOUT
Read Linear
2
D4h
REDA_3V3_POUT
Read Linear
2
D5h
READ_5V_VOUT
Read VOUT Mode
2
D6h
READ_5V_IOUT
Read Linear
2
D7h
READ_5V_POUT
Read Linear
2
FBh
Buzzer_Mute (4)
R/W Byte
1
Note 1:
Status will retain the last occurrence. Latch defined as the status. Must be cleared
through the 03h (CLEAR_FAULTS) command. Please See the following Table.
Command
Status Name
Status action
79h
STATUS_WORD
Latch
7Ah
STATUS_VOUT
Latch
7Bh
STATUS_IOUT
Latch
7Dh
STATUS_TEMPERATURE
Latch
80h
STATUS_OF_3V3 And 5V
Latch
B0h
PSU_STATUS
Automatic recovery
Note 2:
READ_TEMPERATURE_1 should provide the PDB Inlet Ambient temperature.
Note 3:
Read Total Power command only at +12 V, 3V3, 5V total power.
Note 4:
Buzzer will alert when any PSU fault occurs. Write 0x20 command in PMBus will be
able to mute buzzer alarm. When PSU goes back to normal state, the register will be
set at 0x00.
Contents in 20h (VOUT_MODE) Command Code:
Mode
Bits [7:5]
Bits [4:0] (Parameter)
Linear
000b
Five bit two’s complement exponent for the mantissa delivered as
the data bytes for an output voltage related command.
Summary of Contents for ANR-C62-N1 Series
Page 19: ...ANR C62xN1 Series 19 www acrosser com 1 Ear brackets 2 2 5 HDD with sponge ...
Page 21: ...ANR C62xN1 Series 21 www acrosser com 2 2 Slide rail Assembly 1 Slide rail Screw 2 Screw List ...
Page 26: ...ANR C62xN1 Series 26 Acrosser Technology Co Ltd ...
Page 28: ...ANR C62xN1 Series 28 Acrosser Technology Co Ltd Step 5 Lock all the screws back ...