ACROSSER TECHNOLOGY
16
3.2 EOC STATUS REGISTER (BASE+0)
The bit 6 of EOC Status Register is the conversion status
of the A/D converter. This bit will be high(1) during
conversion and will be low(0) when data is available.
Base + 0
D7
D6
D5
D4
D3
D2
D1
D0
X
EOC
X
X
X
X
X
X
EOC End of conversion.
EOC = 0 means the A/D converter is in the auto-zero
configuration and is ready for the next conversion.
The A/D data registers contain valid data of
previous conversions.
EOC = 1 means the A/D converter is busy and the A/D
conversion is in progress.
3.3 CONTROL REGISTER (BASE+1)
Write data to the Control Register controls the operation
of the board. The format of this register is describes as
follows:
Base + 1
D7
D6
D5
D4
D3
D2
D1
D0
X
TRIG
DL
DH
CH3
CH2
CH1
CH0