7.5 CHANGING THE DIMENSIONAL UNIT
7.6 MEASUREMENT
7.7 SWITCHING OFF
7.8 STORAGE
Switch ON the device and press, - key once more to change from mm to inch or vice versa.
1. Switch ON the device.
2. Apply some couplant to the probe.
3. Connect the probe to the car gearbox by turning the bayonet connector.
Measuring positions usually vary depending on the type of vehicle. It is essential that the connecting
positions at the car and at the probe are clean. In order to prevent jamming of the probe, correct orientation during insertion into
the connector is essential. If insertion turns out to be difficult, remove the probe in a careful rotation.
4 Compare the displayed result to the value correlating to the measured oil temperature from the diagnosis instrument.
Do not forget to clean the instrument and to store it in its transport box.
Press and release - key
The instrument has to be stored in the transport box included in the delivery.
Temperature
Displayed value
10 °C / 50°F
54,5 ± 0,3 mm
15 °C / 59°F
54,7 ± 0,3 mm
20 °C / 68°F
54,9 ± 0,3 mm
25 °C / 77°F
55,1 ± 0,3 mm
30 °C / 86°F
55,3 ± 0,3 mm