ACTSmart2 Operating and Installation Manual
Rev. 1.0
4
Installation Notes
• Remember to Factory Default the ACTSmart before programming
• Remember to place the supplied varistor across the terminals of the door strike coil to protect the relay
contacts
• Don’t mount the ACTSmart Prox units near RF sources (Eg mobile phones, radio transmitters,
computer monitors) or metal surfaces.
• Remember that the ACTSmart PIN and Prox units
default to Card operation.
Card and PIN
operation must be programmed in.
(See Programming ACTSmart Options section, Options 39, 40 and
41).
• Don’t power the unit from a switch-mode power supply. Use a linear regulated power supply.
• Never use the on-board relay to switch AC mains voltage. An external relay, electrically isolated from
the ACTSmart should be used for this purpose
• Remember to change the programming code.
• Don’t power the ACTSmart from an AC power supply on a networked system. An AC power supply
may only be used on a standalone ACTSmart.
• The ACTSmart2 version is not compatible with the earlier version of ACTSmart. Cards and fobs for
one version will not work on the other. The devices may NOT be networked together.
Important
As with any Access Control system, always ensure there is an alternate means of escape in the event
of the unit failing to operate due to power loss or in the event of fire.
Product Specification
Number of Users
1000
Supply Voltage
12 - 24 V DC (linear PSU) or AC (standalone only)
Current Consumption
50mA (nominal), 80mA (maximum)
Output Current Sink
100mA
Operating Temperature
-10 to +50 degrees C
Door Open Time
0 - 255 seconds
Max. ACTSmarts per network
8
Length of network
1.4km maximum
Relay Contact Rating
5A / 250Vac
Programmable Inputs
1
Programmable Input/Outputs
2
Controller Size
Flush Mount: 100 x 110 x 20 mm
Surface Mount: 100 x 110 x 35 mm
Controller Weight
200 grams
Water Resistance
High IP67
Construction
Rugged Polycarbonate housing with stainless steel keys and
potted electronics.
Ordering Information
Model
Part Number
ACTSmart
Proximity Only
ACT 1070
ACTSmart
PIN and Proximity
ACT 1080
ACTSmart
PIN Only
ACT 1090