ACTpro DESFIRE EV1 Operating and Installation Manual
Rev 1.0
Reader Output Data Format
Clock and Data
The default data output format from the ACTpro MIFARE DESFire EV1 readers is Clock and Data encoded as
10 BCD digits (also known as Magnetic Stripe Track2 or ABA).
Wiegand
The reader can be configured to output Wiegand formatted data rather that the default clock & data, by
connecting the Sense line to 0V before powering on the reader, this will switch the unit to 37bit Wiegand
output mode.
Wiring Information for “Clock & Data” Output
The standard Clock & Data wiring colours for ACTpro MIFARE DESFire EV1 readers are shown below.
Reader PIN Description
Recommended wiring colour
Description
Sense
White
Direction – connect for entry
Clock / D1
Green
Clock / D1
Data / D0
Blue
Data / D0
12-24 V DC
Red
+ Voltage
0 V
Black
- Voltage
Red Brown Red
LED
Green Yellow
Green
LED
Wiring for Entry / Exit “Clock and Data” Readers
Wiring for “Clock & Data” Entry Reader
Colour
Controller Pin
White Sense
Green
CLOCK / D1
Blue DATA
/
D0
Red +12V
Black 0V
Brown RED
Yellow GREEN
Wiring for “Clock & Data” Exit Reader
Colour
Controller Pin
White
DO NOT CONNECT
Green
CLOCK / D1
Blue DATA
/
D0
Red +12V
Black 0V
Brown RED
Yellow GREEN
2